Literature DB >> 17607762

Tissue response around silicon nitride implants in rabbits.

Cecilia C Guedes e Silva1, Bruno König, Marcelo José Carbonari, Marcelo Yoshimoto, Sérgio Allegrini, José Carlos Bressiani.   

Abstract

The chemical and dimensional stability associated with suitable fracture toughness and propitious tribological characteristics make silicon nitride-based ceramics potential candidates for biomedical applications, mainly as orthopedic implants. Considering this combination of properties, silicon nitride components were investigated in relation to their biocompatibility. For this study, two cylindrical implants were installed in each tibia of five rabbits and were kept in the animals for 8 weeks. During the healing time, tissue tracers were administrated in the animals so as to evaluate the bone growth around the implants. Eight weeks after the surgery, the animals were euthanized and histological analyses were performed. No adverse reactions were observed close to the implant. The osteogenesis process occurred during the entire period defined by the tracers. However, this process occurred more intensely 4 weeks after the surgery. In addition, the histological analyses showed that bone growth occurred preferentially in the cortical areas. Different kinds of tissue were identified on the implant surface, characterized by lamellar bone tissue containing osteocytes and osteons, by a noncalcified matrix containing osteoblasts, or by the presence of collagen III, which may change to collagen I or remain as a fibrous tissue. The results demonstrated that silicon nitride obtained according to the procedure proposed in this research is a biocompatible material. (c) 2007 Wiley Periodicals, Inc. J Biomed Mater Res, 2008.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 17607762     DOI: 10.1002/jbm.a.31363

Source DB:  PubMed          Journal:  J Biomed Mater Res A        ISSN: 1549-3296            Impact factor:   4.396


  5 in total

Review 1.  Silicon Nitride as a Biomedical Material: An Overview.

Authors:  Xiaoyu Du; Seunghun S Lee; Gurdial Blugan; Stephen J Ferguson
Journal:  Int J Mol Sci       Date:  2022-06-11       Impact factor: 6.208

2.  Surface topography of silicon nitride affects antimicrobial and osseointegrative properties of tibial implants in a murine model.

Authors:  Masahiro Ishikawa; Karen L de Mesy Bentley; Bryan J McEntire; B Sonny Bal; Edward M Schwarz; Chao Xie
Journal:  J Biomed Mater Res A       Date:  2017-09-26       Impact factor: 4.396

3.  Elastomeric enriched biodegradable polyurethane sponges for critical bone defects: a successful case study reducing donor site morbidity.

Authors:  Catarina Lavrador; Ramiro Mascarenhas; Paulo Coelho; Cláudia Brites; Alfredo Pereira; Sylwester Gogolewski
Journal:  J Mater Sci Mater Med       Date:  2016-01-22       Impact factor: 3.896

4.  A single center retrospective clinical evaluation of anterior cervical discectomy and fusion comparing allograft spacers to silicon nitride cages.

Authors:  Micah W Smith; Daniel R Romano; Bryan J McEntire; B Sonny Bal
Journal:  J Spine Surg       Date:  2018-06

5.  Biocompatibility of common implantable sensor materials in a tumor xenograft model.

Authors:  Mark E Gray; James Meehan; Ewen O Blair; Carol Ward; Simon P Langdon; Linda R Morrison; Jamie R K Marland; Andreas Tsiamis; Ian H Kunkler; Alan Murray; David Argyle
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2018-10-27       Impact factor: 3.368

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.