Literature DB >> 17606334

Implantation and stability of metallic fiducials within pulmonary lesions.

Patrick A Kupelian1, Alan Forbes, Twyla R Willoughby, Karen Wallace, Rafael R Mañon, Sanford L Meeks, Luis Herrera, Alan Johnston, Juan J Herran.   

Abstract

PURPOSE: To report and describe implantation techniques and stability of metallic fiducials in lung lesions to be treated with external beam radiotherapy. METHODS AND MATERIALS: Patients undergoing radiation therapy for small early-stage lung cancer underwent implantation with small metallic markers. Implantation was either transcutaneous under computed tomographic (CT) or fluoroscopic guidance or transbronchial with the superDimension/Bronchus system (radiofrequency signal-based bronchoscopy guidance related to CT images).
RESULTS: Implantation was performed transcutaneously in 15 patients and transbronchially in 8 patients. Pneumothorax occurred with eight of the 15 transcutaneous implants, six of which required chest tube placement. None of the patients who underwent transbronchial implantation developed pneumothorax. Successfully inserted markers were all usable during gated image-guided radiotherapy. Marker stability was determined by observing the variation in gross target volume (GTV) centroid relative to the marker on repeated CT scans. Average three-dimensional variation in the GTV center relative to the marker was 2.6 +/- 1.3 (SD) mm, and the largest variation along any anatomic axis for any patient was <5 mm. Average GTV volume decrease during the observation period was 34% +/- 23%. Gross tumor volumes do not appear to shrink uniformly about the center of the tumor, but rather the tumor shapes deform substantially throughout treatment.
CONCLUSIONS: Transbronchial marker placement is less invasive than transcutaneous placement, which is associated with high pneumothorax rates. Although marker geometry can be affected by tumor shrinkage, implanted markers are stable within tumors throughout the treatment duration regardless of implantation method.

Entities:  

Mesh:

Year:  2007        PMID: 17606334     DOI: 10.1016/j.ijrobp.2007.03.040

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  21 in total

1.  Evaluation of a template-based algorithm for markerless lung tumour localization on single- and dual-energy kilovoltage images.

Authors:  Alec M Block; Rakesh Patel; Murat Surucu; Matthew M Harkenrider; John C Roeske
Journal:  Br J Radiol       Date:  2016-10-12       Impact factor: 3.039

Review 2.  Improving radiotherapy planning, delivery accuracy, and normal tissue sparing using cutting edge technologies.

Authors:  Carri K Glide-Hurst; Indrin J Chetty
Journal:  J Thorac Dis       Date:  2014-04       Impact factor: 2.895

Review 3.  Role of electromagnetic navigational bronchoscopy in pulmonary nodule management.

Authors:  Aditya Goud; Chanukya Dahagam; David P Breen; Saiyad Sarkar
Journal:  J Thorac Dis       Date:  2016-07       Impact factor: 2.895

4.  The correlation of tissue motion within the lung: implications on fiducial based treatments.

Authors:  Ryan L Smith; Deshan Yang; Andrew Lee; Martin L Mayse; Dan A Low; Parag J Parikh
Journal:  Med Phys       Date:  2011-11       Impact factor: 4.071

Review 5.  Bronchoscopy for the diagnosis of peripheral lung lesions.

Authors:  Samjot Singh Dhillon; Kassem Harris
Journal:  J Thorac Dis       Date:  2017-09       Impact factor: 2.895

Review 6.  Navigational transbronchial needle aspiration, percutaneous needle aspiration and its future.

Authors:  Sixto Arias; Lonny Yarmus; A Christine Argento
Journal:  J Thorac Dis       Date:  2015-12       Impact factor: 2.895

7.  Institutional experience on the treatment of lung and liver lesions with stereotactic body radiotherapy and Novalis Exactrac Adaptive Gating technique.

Authors:  Ovidio Hernando-Requejo; Emilio Sánchez; Pedro Fernández; Daniel Zucca; Juan M Pérez; Mariola García-Aranda; Jeannette Valero; Mercedes López; Raquel Ciérvide; Carmen Rubio
Journal:  J Radiosurg SBRT       Date:  2011

8.  Advances in bronchoscopy for lung cancer.

Authors:  Samjot Singh Dhillon; Elisabeth U Dexter
Journal:  J Carcinog       Date:  2012-12-31

9.  Endovascular coils as lung tumour markers in real-time tumour tracking stereotactic radiotherapy: preliminary results.

Authors:  Jean-Briac G Prévost; Joost J Nuyttens; Mischa S Hoogeman; Johan J Pöll; Lukas C van Dijk; Peter M T Pattynama
Journal:  Eur Radiol       Date:  2008-04-04       Impact factor: 5.315

10.  Minimal Inter-Fractional Fiducial Migration during Image-Guided Lung Stereotactic Body Radiotherapy Using SuperLock Nitinol Coil Fiducial Markers.

Authors:  Yi Rong; Jose G Bazan; Ashley Sekhon; Karl Haglund; Meng Xu-Welliver; Terence Williams
Journal:  PLoS One       Date:  2015-07-09       Impact factor: 3.240

View more