Literature DB >> 17602865

4D medical image computing and visualization of lung tumor mobility in spatio-temporal CT image data.

Heinz Handels1, René Werner, Rainer Schmidt, Thorsten Frenzel, Wei Lu, Daniel Low, Jan Ehrhardt.   

Abstract

The development of 4D CT imaging has introduced the possibility of measuring breathing motion of tumors and inner organs. Conformal thoracic radiation therapy relies on a quantitative understanding of the position of lungs, lung tumors, and other organs during radiation delivery. Using 4D CT data sets, medical image computing and visualization methods were developed to visualize different aspects of lung and lung tumor mobility during the breathing cycle and to extract quantitative motion parameters. A non-linear registration method was applied to estimate the three-dimensional motion field and to compute 3D point trajectories. Specific visualization techniques were used to display the resulting motion field, the tumor's appearance probabilities during a breathing cycle as well as the volume covered by the moving tumor. Furthermore, trajectories of the tumor center-of-mass and organ specific landmarks were computed for the quantitative analysis of tumor and organ motion. The analysis of 4D data sets of seven patients showed that tumor mobility differs significantly between the patients depending on the individual breathing pattern and tumor location.

Entities:  

Mesh:

Year:  2007        PMID: 17602865     DOI: 10.1016/j.ijmedinf.2007.05.003

Source DB:  PubMed          Journal:  Int J Med Inform        ISSN: 1386-5056            Impact factor:   4.046


  3 in total

1.  Estimation of motion fields by non-linear registration for local lung motion analysis in 4D CT image data.

Authors:  René Werner; Jan Ehrhardt; Alexander Schmidt-Richberg; Anabell Heiss; Heinz Handels
Journal:  Int J Comput Assist Radiol Surg       Date:  2010-04-30       Impact factor: 2.924

2.  Changes in cardiac volume determined with repeated enhanced 4DCT during chemoradiotherapy for esophageal cancer.

Authors:  Xue Wang; Jin-Zhi Wang; Jian-Bin Li; Ying-Jie Zhang; Feng-Xiang Li; Wei Wang; Yan-Luan Guo; Qian Shao; Min Xu; Xi-Jun Liu; Yue Wang
Journal:  Radiat Oncol       Date:  2018-09-18       Impact factor: 3.481

3.  Study on the Effect of 4D-CT Special Reconstruction Images for Evaluation of the Cardiac Structure Dose in Radiotherapy for Breast Cancer.

Authors:  Ming Su; Guanzhong Gong; Xiaoping Qiu; Ying Tong; Qian Li; Yong Yin
Journal:  Front Oncol       Date:  2020-03-31       Impact factor: 6.244

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.