Literature DB >> 17598576

Corneal wavefront-guided ablation with the Schwind ESIRIS laser for myopia.

Chuanqing Zhou1, Min Jin, Xiaoyuan Wang, Qiushi Ren.   

Abstract

PURPOSE: To evaluate the outcome of corneal wavefront-guided LASIK for the treatment of myopia and myopic astigmatism.
METHODS: This study included 56 myopic virgin eyes of 28 patients with a mean spherical equivalent refraction of -4.40 +/- 1.83 diopters (D) (range: -1.25 to -9.75 D) and astigmatism < 2.50 D. The corneal wavefront aberrations were analyzed using a corneal topography system. The preoperative corneal wavefront aberration data obtained from the above analyses combined with manifest refraction were used to generate a customized ablation profile. The safety, efficacy, and predictability of the correction, contrast sensitivity, and corneal higher order wavefront aberrations were evaluated.
RESULTS: At 1-year follow-up, the mean residual spherical equivalent refractive error was -0.15 +/- 0.3 D (range: 0 to -1.25 D) and mean cylinder was -0.54 +/- 0.34 D (range: 0 to -1.50 D). Ninety-five percent of eyes were in the residual refractive error range of +/- 0.50 D and uncorrected visual acuity improved by 1.00 D or better in 94% of eyes. The safety index and efficacy index were 1.13 and 0.92, respectively. After treatment, corneal higher order wavefront aberrations with a 6-mm pupil diameter increased significantly (paired sample t test, P < .01), and contrast sensitivity with glare had small reductions at high spatial frequencies. Changes in spherical-like aberration (R = 0.708, P < .001) and higher order wavefront aberration (R = 0.449, P = .001), except for coma-like aberration (P = .238), were positively correlated with the amount of achieved correction.
CONCLUSIONS: Evaluation of clinical results showed that corneal wavefront-guided LASIK for the correction of myopia and myopic astigmatism was safe and effective. There was an increase in all higher order aberrations postoperatively.

Entities:  

Mesh:

Year:  2007        PMID: 17598576     DOI: 10.3928/1081-597X-20070601-07

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  4 in total

1.  Aspheric laser in situ keratomileusis for the correction of myopia using the technolas 217z100: comparison of outcomes versus results from the conventional technique.

Authors:  Akihito Igarashi; Kazutaka Kamiya; Mari Komatsu; Kimiya Shimizu
Journal:  Jpn J Ophthalmol       Date:  2009-10-22       Impact factor: 2.447

2.  The SCHWIND AMARIS Total-Tech Laser as An All-Rounder in Refractive Surgery.

Authors:  Maria Clara Arbelaez; Samuel Arba Mosquera
Journal:  Middle East Afr J Ophthalmol       Date:  2009-01

3.  [Wavefront analysis in ophthalmologic diagnostics].

Authors:  M J Sanchez; A Mannsfeld; A F M Borkenstein; A Ehmer; I-J Limberger; M P Holzer; G U Auffarth
Journal:  Ophthalmologe       Date:  2008-09       Impact factor: 1.059

4.  Comparison of Q-value-guided laser-assisted in situ keratomileusis and standard laser in situ keratomileusis for myopia: A meta-analysis.

Authors:  Kai-Ping Zhang; Xiang Fang; Yin Zhang; Min Chao
Journal:  Medicine (Baltimore)       Date:  2020-11-06       Impact factor: 1.817

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.