Validity of simplified protocols to estimate glomerular filtration rate using iohexol clearance.

T J James1, A V Lewis, G D Tan, P Altmann, R P Taylor, J C Levy.   

Abstract

BACKGROUND: Iohexol clearance is an accurate and precise exogenous marker of glomerular filtration rate (GFR), but protocols are generally lengthy or require multiple sampling. Shorter or simpler protocols would be more practicable.
METHODS: Two clearance estimates, two weeks apart, were undertaken in 11 healthy individuals and 26 diabetic patients with minimal to moderate renal impairment (chronic kidney disease stages 1-3). Blood specimens withdrawn at 60, 90, 120, 150, 180 and 240 min post-iohexol were analysed for iohexol.
RESULTS: Visit 1 demonstrated excellent correlation with visit 2 (slope 1.00, confidence interval [CI] 0.88 to 1.13, intercept 0.94 mL/min/1.73 m(2), CI -9.9 to 11.8, P=0.43). The within-individual coefficient of variation (CV) of the 240 min reference method was 5.4% at a mean GFR of 84.1 mL/min/1.73 m(2). Single point estimates between 120 and 240 min had CVs of 4.5-7.0%, and did not differ from the reference method CV by more than 2.0 mL/min/1.73 m(2). Two and three point estimates in the interval 60-120 min post iohexol injection offered no advantages over these single-point estimates and overestimated at lower GFRs.
CONCLUSIONS: An iohexol clearance estimate of GFR derived from a single sample taken between 2 to 4 h after infusion may provide a suitable tool for routine clinical use.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17594784     DOI: 10.1258/000456307780945804

Source DB:  PubMed          Journal:  Ann Clin Biochem        ISSN: 0004-5632            Impact factor:   2.057


  5 in total

1.  Assessment of the effects of the nitroimidazo-oxazine PA-824 on renal function in healthy subjects.

Authors:  Ann M Ginsberg; Martino W Laurenzi; Doris J Rouse; Karl D Whitney; Mel K Spigelman
Journal:  Antimicrob Agents Chemother       Date:  2009-06-15       Impact factor: 5.191

2.  Validation of a continuous infusion of low dose Iohexol to measure glomerular filtration rate: randomised clinical trial.

Authors:  John J Dixon; Katie Lane; R Neil Dalton; Charles Turner; R Michael Grounds; Iain A M MacPhee; Barbara J Philips
Journal:  J Transl Med       Date:  2015-02-12       Impact factor: 5.531

3.  The diagnostic value of serum creatinine and cystatin c in evaluating glomerular filtration rate in patients with chronic kidney disease: a systematic literature review and meta-analysis.

Authors:  Xilian Qiu; Chunyong Liu; Yuqiu Ye; Hongyong Liu; Huiqun Li; Yanbing Chen; Yongmei Fu; Zhenjie Liu; Xianzhang Huang; Yunqiang Zhang; Xueyuan Liao; Wenbo Zhao; Xun Liu
Journal:  Oncotarget       Date:  2017-08-16

4.  Accuracy of single intravenous access iohexol GFR in children is hampered by marker contamination.

Authors:  Thea Tislevoll Eide; Karl Ove Hufthammer; Atle Brun; Damien Brackman; Einar Svarstad; Camilla Tøndel
Journal:  Sci Rep       Date:  2021-12-01       Impact factor: 4.379

5.  Iohexol plasma clearance for measuring glomerular filtration rate in clinical practice and research: a review. Part 1: How to measure glomerular filtration rate with iohexol?

Authors:  Pierre Delanaye; Natalie Ebert; Toralf Melsom; Flavio Gaspari; Christophe Mariat; Etienne Cavalier; Jonas Björk; Anders Christensson; Ulf Nyman; Esteban Porrini; Giuseppe Remuzzi; Piero Ruggenenti; Elke Schaeffner; Inga Soveri; Gunnar Sterner; Bjørn Odvar Eriksen; Sten-Erik Bäck
Journal:  Clin Kidney J       Date:  2016-08-23
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.