Literature DB >> 17594289

Cardiorespiratory changes during upper gastrointestinal endoscopy.

B B Osinaike1, A Akere, T O Olajumoke, E O Oyebamiji.   

Abstract

OBJECTIVES: To determine the changes in oxygen saturation, blood pressure and heart rate during various endoscopic procedures and to find out the risk factors for these changes.
METHODS: Forty patients without cardiorespiratory disorders were recruited. Oxygen saturation, blood pressure and pulse rate were monitored during endoscopy using pulse oximeter and automated blood pressure monitor. These were recorded from baseline until 5 minutes after the procedure. The important variables, which were evaluated in relation to these changes, included age, gender, duration of the procedure and drug/dosages.
RESULTS: Baseline mean oxygen saturation was 96.8 +/- 1.55%. It decreased significantly to 94.53 +/- 3.30%(p= 0.002) during insertion of probe. Mild to moderate hypoxia was found in 19 (47.5%) patients. Severe hypoxia was found in 5 (12.5%) patients. The variables that reached statistical significance for desaturation were age greater than 50 years and duration longer than 27 minutes. Changes in pulse rate were significant post-sedation, during probe insertion, during scoping, at removal of probe and immediately post-procedure (p < 0.02). The mean change in systolic blood pressure was not significant throughout the procedure when compared to baseline, however 14 (35%) patients developed transient hypertension.
CONCLUSIONS: Mild to moderate hypoxia is common during endoscopic procedures and of no serious consequence. However severe hypoxia is less common. We recommend a non-invasive monitoring in patients with age greater than 50 years and procedure longer than 27 minutes.

Entities:  

Mesh:

Year:  2007        PMID: 17594289      PMCID: PMC1925273          DOI: 10.5555/afhs.2007.7.2.115

Source DB:  PubMed          Journal:  Afr Health Sci        ISSN: 1680-6905            Impact factor:   0.927


  22 in total

1.  A FIBRE OPTIC FLEXIBLE CESOPHAGOSCOPE.

Authors:  B I HIRSCHOWITZ
Journal:  Lancet       Date:  1963-08-24       Impact factor: 79.321

2.  Electrocardiographic changes during upper gastrointestinal endoscopy in ambient hypoxia.

Authors:  H S Malhotra; S Rana; L S Pal; D J Dasgupta
Journal:  J Assoc Physicians India       Date:  1991-09

Review 3.  Sedation and monitoring for gastrointestinal endoscopy.

Authors:  M L Freeman
Journal:  Gastrointest Endosc Clin N Am       Date:  1994-07

4.  Role of pulse oximetry during nonsedated upper gastrointestinal endoscopic procedures.

Authors:  G Javid; B Khan; M M Wani; A Shah; G M Gulzar; B Khan
Journal:  Indian J Gastroenterol       Date:  1999 Jan-Mar

5.  Carbon dioxide retention and oxygen desaturation during gastrointestinal endoscopy.

Authors:  M L Freeman; J T Hennessy; O W Cass; A M Pheley
Journal:  Gastroenterology       Date:  1993-08       Impact factor: 22.682

6.  Clinical value of pulse oximetry during routine diagnostic and therapeutic endoscopic procedures.

Authors:  J C Berg; R Miller; E Burkhalter
Journal:  Endoscopy       Date:  1991-11       Impact factor: 10.093

7.  Cardiovascular responses, arterial oxygen saturation and plasma catecholamine concentration during upper gastrointestinal endoscopy using conscious sedation with midazolam or propofol.

Authors:  V L Oei-Lim; C J Kalkman; J F Bartelsman; J C Res; H B van Wezel
Journal:  Eur J Anaesthesiol       Date:  1998-09       Impact factor: 4.330

8.  Effect of supplemental oxygen on cardiopulmonary changes during gastrointestinal endoscopy.

Authors:  K R Jurell; K W O'Connor; J Slack; J Fraiz; C J Shaar; L Kent; R Callon
Journal:  Gastrointest Endosc       Date:  1994 Nov-Dec       Impact factor: 9.427

9.  Oxygen desaturation and tachycardia during upper gastrointestinal endoscopy are transient and benign.

Authors:  F P Mistry; P Abraham; S J Bhatia
Journal:  J Assoc Physicians India       Date:  1992-08

10.  Sedation for upper gastrointestinal endoscopy: a comparison of alfentanil-midazolam and meperidine-diazepam.

Authors:  M B Donnelly; W A Scott; D S Daly
Journal:  Can J Anaesth       Date:  1994-12       Impact factor: 5.063

View more
  2 in total

1.  Safety of gastrointestinal endoscopy with conscious sedation in obstructive sleep apnea.

Authors:  Christian M Andrade; Brijesh Patel; Meghana Vellanki; Ambuj Kumar; Gitanjali Vidyarthi
Journal:  World J Gastrointest Endosc       Date:  2017-11-16

2.  Continuous non-invasive arterial pressure technique improves patient monitoring during interventional endoscopy.

Authors:  Sylvia Siebig; Felix Rockmann; Karl Sabel; Ina Zuber-Jerger; Christine Dierkes; Tanja Brünnler; Christian E Wrede
Journal:  Int J Med Sci       Date:  2009-01-20       Impact factor: 3.738

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.