Enhanced electrochemiluminescence sensor from tris(2,2'-bipyridyl)ruthenium(II) incorporated into MCM-41 and an ionic liquid-based carbon paste electrode.

Jing Li1, Minghua Huang, Xiaoqing Liu, Hui Wei, Yuanhong Xu, Guobao Xu, Erkang Wang.   

Abstract

The electrochemiluminescence (ECL) of tris(2,2'-bipyridyl)ruthenium(II) [Ru(bpy)(3)(2+)] ion-exchanged in the sulfonic-functionalized MCM-41 silicas was developed with tripropylamine (TPrA) as a co-reactant in a carbon paste electrode (CPE) using a room temperature ionic liquid (IL) as a binder. The sulfonic-functionalized silicas MCM-41 were used for preparing an ECL sensor by the electrostatic interactions between Ru(bpy)(3)(2+) cations and sulfonic acid groups. We used the IL as a binder to construct the CPE (IL-CPE) to replace the traditional binder of the CPE (T-CPE)--silicone oil. The results indicated that the MCM-41-modified IL-CPE had more open structures to allow faster diffusion of Ru(bpy)(3)(2+) and that the ionic liquid also acted as a conducting bridge to connect TPrA with Ru(bpy)(3)(2+) sites immobilized in the electrode, resulting in a higher ECL intensity compared with the MCM-41-modified T-CPE. Herein, the detection limit for TPrA of the MCM-41-modified IL-CPE was 7.2 nM, which was two orders of magnitude lower than that observed at the T-CPE. When this new sensor was used in flow injection analysis (FIA), the MCM-41-modified IL-CPE ECL sensor also showed good reproducibility. Furthermore, the sensor could also be renewed easily by mechanical polishing whenever needed.

Entities:  

Year:  2007        PMID: 17592588     DOI: 10.1039/b701842h

Source DB:  PubMed          Journal:  Analyst        ISSN: 0003-2654            Impact factor:   4.616


  3 in total

1.  Micromolded Carbon Paste Microelectrodes for Electrogenerated Chemiluminescent Detection on Microfluidic Devices.

Authors:  Erin M Gross; Laura R Porter; Nicholas R Stukel; Emily R Lowry; Leah V Schaffer; Sai Sujana Maddipati; Dylan J Hoyt; Sarah E Stombaugh; Sarah R Peila; Charles S Henry
Journal:  ChemElectroChem       Date:  2020-05-07       Impact factor: 4.590

Review 2.  Ruthenium polypyridine complexes combined with oligonucleotides for bioanalysis: a review.

Authors:  Shuyu Zhang; Yubin Ding; Hui Wei
Journal:  Molecules       Date:  2014-08-11       Impact factor: 4.411

Review 3.  Fabrication, Flow Control, and Applications of Microfluidic Paper-Based Analytical Devices.

Authors:  Hosub Lim; Ali Turab Jafry; Jinkee Lee
Journal:  Molecules       Date:  2019-08-07       Impact factor: 4.411

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.