Literature DB >> 17592010

Dispensing error rate after implementation of an automated pharmacy carousel system.

Scott Oswald1, Richard Caldwell.   

Abstract

PURPOSE: A study was conducted to determine filling and dispensing error rates before and after the implementation of an automated pharmacy carousel system (APCS).
METHODS: The study was conducted in a 613-bed acute and tertiary care university hospital. Before the implementation of the APCS, filling and dispensing rates were recorded during October through November 2004 and January 2005. Postimplementation data were collected during May through June 2006. Errors were recorded in three areas of pharmacy operations: first-dose or missing medication fill, automated dispensing cabinet fill, and interdepartmental request fill. A filling error was defined as an error caught by a pharmacist during the verification step. A dispensing error was defined as an error caught by a pharmacist observer after verification by the pharmacist.
RESULTS: Before implementation of the APCS, 422 first-dose or missing medication orders were observed between October 2004 and January 2005. Independent data collected in December 2005, approximately six weeks after the introduction of the APCS, found that filling and error rates had increased. The filling rate for automated dispensing cabinets was associated with the largest decrease in errors. Filling and dispensing error rates had decreased by December 2005. In terms of interdepartmental request fill, no dispensing errors were noted in 123 clinic orders dispensed before the implementation of the APCS. One dispensing error out of 85 clinic orders was identified after implementation of the APCS.
CONCLUSION: The implementation of an APCS at a university hospital decreased medication filling errors related to automated cabinets only and did not affect other filling and dispensing errors.

Mesh:

Year:  2007        PMID: 17592010     DOI: 10.2146/ajhp060313

Source DB:  PubMed          Journal:  Am J Health Syst Pharm        ISSN: 1079-2082            Impact factor:   2.637


  13 in total

1.  Medication administration errors in nursing homes using an automated medication dispensing system.

Authors:  Patricia M L A van den Bemt; Jetske C Idzinga; Hans Robertz; Dennis Groot Kormelink; Neske Pels
Journal:  J Am Med Inform Assoc       Date:  2009-04-23       Impact factor: 4.497

2.  Medication dispensing errors in a French military hospital pharmacy.

Authors:  Xavier Bohand; Olivier Aupée; Patrick Le Garlantezec; Hélène Mullot; Leslie Lefeuvre; Laurent Simon
Journal:  Pharm World Sci       Date:  2009-03-21

3.  Safeguarding the process of drug administration with an emphasis on electronic support tools.

Authors:  Hanna M Seidling; Anette Lampert; Kristina Lohmann; Julia T Schiele; Alexander J F Send; Diana Witticke; Walter E Haefeli
Journal:  Br J Clin Pharmacol       Date:  2013-09       Impact factor: 4.335

4.  Towards improving dose administration aid supply: a quality improvement intervention aimed at reducing dispensing errors.

Authors:  Julia Fiona-Maree Gilmartin; Jennifer Lillian Marriott; Safeera Yasmeen Hussainy
Journal:  Int J Clin Pharm       Date:  2013-08-23

5.  Critical Evaluation of Pharmacy Automation and Robotic Systems: A Call to Action.

Authors:  Anthony M Boyd; Bruce W Chaffee
Journal:  Hosp Pharm       Date:  2018-07-09

6.  Community pharmacists' attitudes toward dispensing errors at community pharmacy setting in Central Saudi Arabia.

Authors:  Mohamed N Al-Arifi
Journal:  Saudi Pharm J       Date:  2013-05-29       Impact factor: 4.330

7.  Medication errors: the importance of safe dispensing.

Authors:  Ka-Chun Cheung; Marcel L Bouvy; Peter A G M De Smet
Journal:  Br J Clin Pharmacol       Date:  2009-06       Impact factor: 4.335

8.  Frequency, types, and potential clinical significance of medication-dispensing errors.

Authors:  Xavier Bohand; Laurent Simon; Eric Perrier; Hélène Mullot; Leslie Lefeuvre; Christian Plotton
Journal:  Clinics (Sao Paulo)       Date:  2009       Impact factor: 2.365

9.  Medication incidents related to automated dose dispensing in community pharmacies and hospitals--a reporting system study.

Authors:  Ka-Chun Cheung; Patricia M L A van den Bemt; Marcel L Bouvy; Michel Wensing; Peter A G M De Smet
Journal:  PLoS One       Date:  2014-07-24       Impact factor: 3.240

10.  Incidence of patient safety events and process-related human failures during intra-hospital transportation of patients: retrospective exploration from the institutional incident reporting system.

Authors:  Shu-Hui Yang; Jih-Shuin Jerng; Li-Chin Chen; Yu-Tsu Li; Hsiao-Fang Huang; Chao-Ling Wu; Jing-Yuan Chan; Szu-Fen Huang; Huey-Wen Liang; Jui-Sheng Sun
Journal:  BMJ Open       Date:  2017-11-03       Impact factor: 2.692

View more