An electrode array that minimizes blood loss for radiofrequency-assisted hepatic resection.

D J Schutt1, A P O'Rourke, J A Will, J G Webster, D M Mahvi, D Haemmerich.   

Abstract

Hepatic resection is currently the standard treatment for liver cancer. During hepatic resection part of the liver containing the tumor is surgically removed. This type of surgery is accompanied by high blood loss of approximately 0.6-1.35 L. Blood loss is associated with increased complication rates, prolonged hospital stay, and reduced patient survival, especially when transfusion is required. Other researchers have suggested using radiofrequency (rf) or microwave ablation to coagulate a tissue slice before resection to reduce blood loss, but conventional devices typically take several hours. We developed a device consisting of a linear array of blade-shaped, 1 cm wide radiofrequency (rf) electrodes 1.5 cm apart. Bipolar rf power is applied between pairs of adjacent electrodes, leading to high tissue temperatures between the electrodes that promote coagulation of large vessels (>3 mm) in the resection plane. Rapid switching of applied power between pairs of adjacent electrodes allows simultaneous heating and coagulation of the entire resection plane within 3-6 min. In seven in vivo trials in a porcine model, resection along a plane pre-coagulated with the device resulted in little (<20 mL) to no blood loss, while coagulating all vessels (up to 4.5 mm diameter in this study). Average treatment time (from placement of the device to transection) was 6.8+/-0.5 min when four electrodes were used, and 11.3+/-1.2 min when 5-7 electrodes were used. This device may reduce blood loss related morbidity during resection and reduce treatment time by coagulating all vessels in the resection plane.

Entities:  

Mesh:

Year:  2007        PMID: 17588799      PMCID: PMC2446607          DOI: 10.1016/j.medengphy.2007.05.004

Source DB:  PubMed          Journal:  Med Eng Phys        ISSN: 1350-4533            Impact factor:   2.242


  18 in total

Review 1.  Surgical treatment of malignant liver tumours.

Authors:  R P DeMatteo; Y Fong; L H Blumgart
Journal:  Baillieres Best Pract Res Clin Gastroenterol       Date:  1999-12

2.  Early experience employing a linear hepatic parenchyma coagulation device.

Authors:  Cord Sturgeon; W Scott Helton; Amit Lamba; Gregorio Chejfec; N Joseph Espat
Journal:  J Hepatobiliary Pancreat Surg       Date:  2003

3.  One hundred and fifty hepatic resections: evolution of technique towards bloodless surgery.

Authors:  M Rees; G Plant; J Wells; S Bygrave
Journal:  Br J Surg       Date:  1996-11       Impact factor: 6.939

4.  Microwave surgery in the treatment of hepatocellular carcinoma.

Authors:  X D Zhou; Z Y Tang; Y Q Yu; Z C Ma; D B Xu; Y X Zheng; B H Zhang
Journal:  Semin Surg Oncol       Date:  1993 Jul-Aug

5.  Prognostic factors and survival after hepatic resection for hepatocellular carcinoma without cirrhosis.

Authors:  N Nagasue; T Ono; A Yamanoi; H Kohno; O N El-Assal; H Taniura; M Uchida
Journal:  Br J Surg       Date:  2001-04       Impact factor: 6.939

6.  Predictors of successful hepatic resection: prognostic usefulness of hepatic asialoglycoprotein receptor analysis.

Authors:  Norihiro Kokudo; David R Vera; Keiichiro Tada; Mitsuru Koizumi; Makoto Seki; Toshiki Matsubara; Hirotoshi Ohta; Toshiharu Yamaguchi; Takashi Takahashi; Toshifusa Nakajima; Tetsuichiro Muto
Journal:  World J Surg       Date:  2002-09-26       Impact factor: 3.352

7.  Haemostatic partial nephrectomy using bipolar radiofrequency ablation.

Authors:  Gyan Pareek; Eric R Wilkinson; David Schutt; James A Will; Thomas F Warner; Dieter Haemmerich; David Mahvi; Stephen Y Nakada
Journal:  BJU Int       Date:  2005-11       Impact factor: 5.588

8.  A new technological approach to nonanatomical pulmonary resection: saline enhanced thermal sealing.

Authors:  Anthony P C Yim; Erino A Rendina; Stephen R Hazelrigg; Louis T C Chow; Tai-Wai Lee; Song Wan; Ahmed A Arifi
Journal:  Ann Thorac Surg       Date:  2002-11       Impact factor: 4.330

9.  Influence of transfusions on perioperative and long-term outcome in patients following hepatic resection for colorectal metastases.

Authors:  David A Kooby; Jennifer Stockman; Leah Ben-Porat; Mithat Gonen; William R Jarnagin; Ronald P Dematteo; Scott Tuorto; David Wuest; Leslie H Blumgart; Yuman Fong
Journal:  Ann Surg       Date:  2003-06       Impact factor: 12.969

10.  Hepatic bipolar radiofrequency ablation creates coagulation zones close to blood vessels: a finite element study.

Authors:  D Haemmerich; A W Wright; D M Mahvi; F T Lee; J G Webster
Journal:  Med Biol Eng Comput       Date:  2003-05       Impact factor: 2.602

View more
  2 in total

1.  A surgical device for radiofrequency ablation of large liver tumors.

Authors:  I dos Santos; D Correia; A J M Soares; J A Góes; A F da Rocha; D Schutt; D Haemmerich
Journal:  Physiol Meas       Date:  2008-09-24       Impact factor: 2.833

2.  Technical development of a new semispherical radiofrequency bipolar device (RONJA): ex vivo and in vivo studies.

Authors:  Petr Vavra; Marek Penhaker; Jan Grepl; Jana Jurcikova; Jiri Palecek; Michal Crha; Jana Nowakova; Martin Hasal; Martina Skrobankova; Petr Ostruszka; Peter Ihnat; Patricie Delongova; Dana Salounova; Nagy A Habib; Pavel Zonca
Journal:  Biomed Res Int       Date:  2014-04-09       Impact factor: 3.411

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.