Literature DB >> 17588592

Hydrophilic interaction liquid chromatographic analysis of aminohydroxyphenylalanines from melanin pigments.

Dzeneta Nezirević1, Kerstin Arstrand, Bertil Kågedal.   

Abstract

Malignant melanomas are more often seen in subjects with light colored skin who tan poorly than in persons who tan more rapidly. This has been attributed to the structure of their pigment, pheomelanin, which differs markedly from the eumelanin of persons with darker skin. To study the hydrolysis products of pheomelanin pigments a new method was developed for analysis of 4-amino-3-hydroxyphenylalanine (4-AHP) and 3-amino-4-hydroxyphenylalanine (3-AHP). Pheomelanin samples were hydrolyzed and extracted with solid-phase extraction columns using strong cation-exchange (SCX) cartridges. Separation of 4-AHP and 3-AHP was achieved on a ZIC-HILIC column (150 mm x 2.1mm I.D.) with a mobile phase consisting of acetonitrile: 0.1 M ammonium acetate buffer, pH 4.5 (82:18, v/v). Detection was performed with an electrochemical detector at +400 mV. Run time was 30 min. The limits of detection were 73 pg and 51 pg for 4-AHP and 3-AHP respectively, using 2 microl injections. Good linearity was found within the range 0.05-5.0 microg/ml. Absolute recovery was 70% and relative recovery was 100%. The AHPs were stable for 1 year in the hydrolyzed samples, for 4 days in the eluates from solid-phase sorbents stored in the refrigerator, and for 2 days diluted with mobile phase and stored in the autosampler at 10 degrees C. The within-day imprecision was <5% and the between-day imprecision was <7% for the two analytes. The method, applied to the analysis of pheomelanin in urine from human melanoma patients, allows the analysis of 30 samples in one set and is suitable for routine work with human hair and melanoma cells. By using the ZIC-HILIC stationary phase, ion-pairing reagents could be avoided, which makes the method suitable to further analysis of degradation products from pheomelanins using mass spectrometric detection.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17588592     DOI: 10.1016/j.chroma.2007.06.007

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  2 in total

1.  Melanins as biomarkers of ovarian follicular atresia in the catfish Heteropneustes fossilis: biochemical and histochemical characterization, seasonal variation and hormone effects.

Authors:  Ravi Kumar; Keerikkattil P Joy
Journal:  Fish Physiol Biochem       Date:  2015-03-21       Impact factor: 2.794

Review 2.  From Extraction to Advanced Analytical Methods: The Challenges of Melanin Analysis.

Authors:  Ioana-Ecaterina Pralea; Radu-Cristian Moldovan; Alina-Maria Petrache; Maria Ilieș; Simona-Codruța Hegheș; Irina Ielciu; Raul Nicoară; Mirela Moldovan; Mihaela Ene; Mihai Radu; Alina Uifălean; Cristina-Adela Iuga
Journal:  Int J Mol Sci       Date:  2019-08-13       Impact factor: 5.923

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.