Directly measured cabin pressure conditions during Boeing 747-400 commercial aircraft flights.

Paul T Kelly1, Leigh M Seccombe, Peter G Rogers, Matthew J Peters.   

Abstract

BACKGROUND AND OBJECTIVES: In the low pressure environment of commercial aircraft, hypoxaemia may be common and accentuated in patients with lung or heart disease. Regulations specify a cabin pressure not lower than 750 hPa but it is not known whether this standard is met. This knowledge is important in determining the hazards of commercial flight for patients and the validity of current flight simulation tests.
METHODS: Using a wrist-watch recording altimeter, cabin pressure was recorded at 60 s intervals on 45 flights in Boeing 747-400 aircraft with three airlines. A log was kept of aircraft altitude using the in-flight display. Change in cabin pressure during flight, relationship between aircraft altitude and cabin pressure and proportion of flight time with cabin pressure approaching the minimum specified by regulation were determined.
RESULTS: Flight duration averaged 10 h. Average cabin pressure during flight was 846 hPa. There was a linear fall in cabin pressure as the aircraft cruising altitude increased. At 10,300 m (34,000 ft) cabin pressure was 843 hPa and changed 8 hPa for every 300 m (1000 ft) change in aircraft altitude (r(2) = 0.993; P < 0.001). Lowest cabin pressure was 792 hPa at 12 200 m (40,000 ft) but during only 2% of flight time was cabin pressure less than 800 hPa.
CONCLUSIONS: Cabin pressure is determined only by the engineering of the aircraft and its altitude and in the present study was always higher than required by regulation. Current fitness-to-fly evaluations simulate cabin conditions that passengers will not experience on these aircraft. There may be increased risks to patients should new or older aircraft operate nearer to the present minimum standard.

Entities:  

Mesh:

Year:  2007        PMID: 17587417     DOI: 10.1111/j.1440-1843.2007.01104.x

Source DB:  PubMed          Journal:  Respirology        ISSN: 1323-7799            Impact factor:   6.424


  7 in total

Review 1.  Headache and Barometric Pressure: a Narrative Review.

Authors:  Kushagra Maini; Nathaniel M Schuster
Journal:  Curr Pain Headache Rep       Date:  2019-11-09

2.  Headaches attributed to airplane travel: a Danish survey.

Authors:  Sebastian Bao Dinh Bui; Torben Petersen; Jeppe Nørgaard Poulsen; Parisa Gazerani
Journal:  J Headache Pain       Date:  2016-04-14       Impact factor: 7.277

3.  Right heart function during simulated altitude in patients with pulmonary arterial hypertension.

Authors:  Leigh M Seccombe; Vincent Chow; Wei Zhao; Edmund M T Lau; Peter G Rogers; Austin C C Ng; Elizabeth M Veitch; Matthew J Peters; Leonard Kritharides
Journal:  Open Heart       Date:  2017-01-20

4.  Simulated airplane headache: a proxy towards identification of underlying mechanisms.

Authors:  Sebastian Bao Dinh Bui; Torben Petersen; Jeppe Nørgaard Poulsen; Parisa Gazerani
Journal:  J Headache Pain       Date:  2017-01-28       Impact factor: 7.277

Review 5.  Headache attributed to airplane travel: diagnosis, pathophysiology, and treatment - a systematic review.

Authors:  Sebastian Bao Dinh Bui; Parisa Gazerani
Journal:  J Headache Pain       Date:  2017-08-16       Impact factor: 7.277

6.  Risk for intracranial pressure increase related to enclosed air in post-craniotomy patients during air ambulance transport: a retrospective cohort study with simulation.

Authors:  Helge Brändström; Anna Sundelin; Daniela Hoseason; Nina Sundström; Richard Birgander; Göran Johansson; Ola Winsö; Lars-Owe Koskinen; Michael Haney
Journal:  Scand J Trauma Resusc Emerg Med       Date:  2017-05-12       Impact factor: 2.953

7.  In-Flight Hypoxemia in a Tracheostomy-Dependent Infant.

Authors:  Jason Quevreaux; Christopher Cropsey
Journal:  Case Rep Anesthesiol       Date:  2017-02-28
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.