Literature DB >> 17586852

Comparison of conventional and cone beam CT synthesized cephalograms.

V Kumar1, J B Ludlow, A Mol, L Cevidanes.   

Abstract

OBJECTIVES: To compare cephalometric measurements from synthesized cone beam CT (CBCT) lateral cephalograms using orthogonal and perspective projections with those from conventional cephalometric radiographs and dry skulls.
METHODS: Ten skulls were imaged using CBCT and conventional cephalometry. CBCT volume data were exported in DICOM format and imported in Dolphin 3D (pre-release version). Orthogonal and perspective lateral cephalometric radiographs were created from 3D virtual models. Nine linear and five angular measurements were made in Dolphin at three different times. Three calliper measures of midsagittal landmarks were made directly onto skulls. Perspective and conventional image measurements were corrected for known magnification. Reproducibility of measurements was assessed using multivariate analysis of variance (MANOVA). Linear and angular measurements were compared between image modalities by measurement using a repeated measures MANOVA model. Differences and absolute value of differences between image measurements and skull measurements were assessed using analysis of variance (ANOVA).
RESULTS: Measurements were not different between the imaging modalities (P>0.05), except for the mandibular unit length (P=0.01). Linear midsagittal measurements were significantly greater than skull measurements for perspective CBCT and significantly less than skull measurements for conventional images (P=0.003). Precision of orthogonal CBCT midsagittal linear measurements was significantly better than the other modalities (P=0.007). Orthogonal CBCT projections provided more accurate midsagittal skull measurements than perspective CBCT or conventional cephalometric radiographs.
CONCLUSIONS: CBCT can reproduce conventional cephalometric geometry with similar precision and accuracy. Orthogonal CBCT projections provided greater accuracy of measurement for midsagittal plane dimensions than perspective CBCT or conventional cephalometric images.

Entities:  

Mesh:

Year:  2007        PMID: 17586852     DOI: 10.1259/dmfr/98032356

Source DB:  PubMed          Journal:  Dentomaxillofac Radiol        ISSN: 0250-832X            Impact factor:   2.419


  48 in total

1.  Comparative study between conventional and cone beam CT-synthesized half and total skull cephalograms.

Authors:  G S Liedke; E L Delamare; M B Vizzotto; H L D da Silveira; J R Prietsch; V Dutra; H E D da Silveira
Journal:  Dentomaxillofac Radiol       Date:  2012-02       Impact factor: 2.419

2.  Comparison of linear and angular measurements using two-dimensional conventional methods and three-dimensional cone beam CT images reconstructed from a volumetric rendering program in vivo.

Authors:  U Oz; K Orhan; N Abe
Journal:  Dentomaxillofac Radiol       Date:  2011-12       Impact factor: 2.419

Review 3.  Use of cone beam computed tomography in otolaryngologic treatments.

Authors:  Hamdi Cakli; Cemal Cingi; Yazgi Ay; Fatih Oghan; Torun Ozer; Ercan Kaya
Journal:  Eur Arch Otorhinolaryngol       Date:  2011-09-27       Impact factor: 2.503

4.  Measurements on 3D models of human skulls derived from two different cone beam CT scanners.

Authors:  Olivier J C van Vlijmen; Frits A Rangel; Stefaan J Bergé; Ewald M Bronkhorst; Alfred G Becking; Anne Marie Kuijpers-Jagtman
Journal:  Clin Oral Investig       Date:  2010-07-17       Impact factor: 3.573

5.  Evaluation of the accuracy of linear measurements on spiral computed tomography-derived three-dimensional images and its comparison with digital cephalometric radiography.

Authors:  S Varghese; V Kailasam; S Padmanabhan; B Vikraman; A Chithranjan
Journal:  Dentomaxillofac Radiol       Date:  2010-05       Impact factor: 2.419

6.  Accuracy assessment of the axial images obtained from cone beam computed tomography.

Authors:  Francine Kühl Panzarella; J L C Junqueira; L B Oliveira; N S de Araújo; C Costa
Journal:  Dentomaxillofac Radiol       Date:  2011-09       Impact factor: 2.419

7.  Accuracy of linear measurement using cone-beam computed tomography at different reconstruction angles.

Authors:  Sima Nikneshan; Shadi Hamidi Aval; Neema Bakhshalian; Shahriyar Shahab; Mahdis Mohammadpour; Soodeh Sarikhani
Journal:  Imaging Sci Dent       Date:  2014-11-25

Review 8.  CBCT in orthodontics: assessment of treatment outcomes and indications for its use.

Authors:  S D Kapila; J M Nervina
Journal:  Dentomaxillofac Radiol       Date:  2015       Impact factor: 2.419

9.  Assessment of morphological and anatomical characteristics of mental foramen using cone beam computed tomography.

Authors:  Samir Goyushov; Melek Didem Tözüm; Tolga Fikret Tözüm
Journal:  Surg Radiol Anat       Date:  2018-05-25       Impact factor: 1.246

10.  Accuracy and landmark error calculation using cone-beam computed tomography-generated cephalograms.

Authors:  Dan Grauer; Lucia S H Cevidanes; Martin A Styner; Inam Heulfe; Eric T Harmon; Hongtu Zhu; William R Proffit
Journal:  Angle Orthod       Date:  2010-03       Impact factor: 2.079

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.