Abstract

PURPOSE: To describe the design of a new intraocular lens (IOL) capable of correcting spherical and chromatic aberrations when implanted in the human eye.
SETTING: University of Murcia, Murcia, and University of Valencia, Valencia, Spain.
METHODS: A hybrid singlet achromatic IOL was designed. The IOL has a combination of a refractive and a diffractive surface, with 1 of the surfaces being aspherical. Optical simulations were used to model the polychromatic modulation transfer function (MTF) in pseudophakic eyes to explain the differences in optical quality afforded by the achromatic IOL. Parameters such as focus shift, optical path difference, through-focus, and robustness to tilt and decentering of achromatic IOLs were obtained.
RESULTS: The polychromatic MTF in an eye with a centered, not tilted achromatic IOL was near the diffraction-limited MTF. The focus shift change for the achromatic IOL through the visible spectrum was approximately 0.1 diopter. The polychromatic MTF in an eye with the achromatic IOL would be similar to that in an eye with a spherically centered IOL if the achromatic IOL were decentered 1.0 mm or tilted 4 degrees. The range of centration and tilt error for the achromatic IOL to obtain an optical benefit in the polychromatic MTF was larger than the typical postoperative IOL decentration and tilt errors.
CONCLUSION: The hybrid singlet achromatic IOL design resolved the chromatic aberration problem, improving the overall optical quality in the human eye.

Entities:  

Mesh:

Year:  2007        PMID: 17586390     DOI: 10.1016/j.jcrs.2007.03.041

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  6 in total

1.  Comparison of contrast sensitivity, depth of field and ocular wavefront aberrations in eyes with an IOL with zero versus positive spherical aberration.

Authors:  Jay S Pepose; Mujtaba A Qazi; Keith H Edwards; Jeff P Sanderson; Edwin J Sarver
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2009-03-11       Impact factor: 3.117

2.  Extended depth of focus intraocular lens: Chromatic performance.

Authors:  Maria S Millán; Fidel Vega
Journal:  Biomed Opt Express       Date:  2017-08-31       Impact factor: 3.732

3.  Evolution of visual performance in 70 eyes implanted with the Tecnis(®) ZMB00 multifocal intraocular lens.

Authors:  Carlos Palomino Bautista; David Carmona González; Alfredo Castillo Gómez
Journal:  Clin Ophthalmol       Date:  2012-03-21

4.  Retinal image contrast obtained by a model eye with combined correction of chromatic and spherical aberrations.

Authors:  Kazuhiko Ohnuma; Hiroyuki Kayanuma; Tjundewo Lawu; Kazuno Negishi; Takefumi Yamaguchi; Toru Noda
Journal:  Biomed Opt Express       Date:  2011-05-06       Impact factor: 3.732

5.  Prospective comparative study of tolerance to refractive errors after implantation of extended depth of focus and monofocal intraocular lenses with identical aspheric platform in Korean population.

Authors:  Hyeck-Soo Son; Seong Ho Kim; Gerd U Auffarth; Chul Young Choi
Journal:  BMC Ophthalmol       Date:  2019-08-19       Impact factor: 2.209

6.  Visual and Refractive Outcomes following Bilateral Implantation of Extended Range of Vision Intraocular Lens with Micromonovision.

Authors:  Sri Ganesh; Sheetal Brar; Archana Pawar; Kirti J Relekar
Journal:  J Ophthalmol       Date:  2018-02-06       Impact factor: 1.909

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.