Literature DB >> 17585916

Transabdominal ultrasound assessment of the fetal head and the accuracy of vacuum cup application.

G Y Wong1, Y M Mok, S F Wong.   

Abstract

OBJECTIVE: To investigate whether the accuracy of vacuum cup placement can be improved by intrapartum ultrasound assessment of the fetal head position during the second stage of labor prior to vacuum extraction for prolonged second stage.
METHODS: 50 women undergoing vacuum extraction for prolonged second stage were randomly allocated to either digital examination (n=25) or digital examination together with transabdominal intrapartum ultrasound (n=25) prior to vacuum extraction by the attending obstetrician. The distance between the centre of the chignon and the flexion point was then measured by a midwife immediately after delivery. The flexion point was defined as 6 cm posterior to the anterior fontanelle or 3 cm anterior to the posterior fontanelle.
RESULTS: There were no statistically significant differences in the demographic data, duration of labor, incidence of induction/augmentation, and intrapartum complications between the two groups. The mean distance between the centre of the chignon and the flexion point was 2.1+/-1.3 cm in the group with digital examination and ultrasound assessment and 2.8+/-1.0 cm in the group with digital examination alone. The difference in the mean distance between the two groups was statistically significant (p=0.039).
CONCLUSION: Intrapartum transabdominal ultrasound assessment of the fetal head position during the second stage of labor improves the accuracy of vacuum cup placement during vacuum extraction for prolonged second stage.

Entities:  

Mesh:

Year:  2007        PMID: 17585916     DOI: 10.1016/j.ijgo.2007.05.021

Source DB:  PubMed          Journal:  Int J Gynaecol Obstet        ISSN: 0020-7292            Impact factor:   3.561


  4 in total

1.  Dynamic Changes in the Myometrium during the Third Stage of Labor, Evaluated Using Two-Dimensional Ultrasound, in Women with Normal and Abnormal Third Stage of Labor and in Women with Obstetric Complications.

Authors:  Manasi Patwardhan; Edgar Hernandez-Andrade; Hyunyoung Ahn; Steven J Korzeniewski; Alyse Schwartz; Sonia S Hassan; Roberto Romero
Journal:  Gynecol Obstet Invest       Date:  2015-01-28       Impact factor: 2.031

2.  Study protocol. IDUS - Instrumental delivery & ultrasound: a multi-centre randomised controlled trial of ultrasound assessment of the fetal head position versus standard care as an approach to prevent morbidity at instrumental delivery.

Authors:  Deirdre J Murphy; Gerard Burke; Alan A Montgomery; Meenakshi Ramphul
Journal:  BMC Pregnancy Childbirth       Date:  2012-09-13       Impact factor: 3.007

3.  Acceptability of Intrapartum Ultrasound Monitoring - Experience from a Romanian Longitudinal Study.

Authors:  D G Iliescu; S Tudorache; M L Cara; R Dragusin; O Carbunaru; M Florea; C Patru; L Zorila; A Dragoescu; L Novac; N Cernea
Journal:  Curr Health Sci J       Date:  2015-12-22

4.  Fetal Head Position during the First Stage of Labor: Comparison between Vaginal Examination and Transabdominal Ultrasound.

Authors:  Jyothi Shetty; Vinod Aahir; Deeksha Pandey; Prashanth Adiga; Asha Kamath
Journal:  ISRN Obstet Gynecol       Date:  2014-03-27
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.