Literature DB >> 17581907

Uterine fibroid embolization: the utility of aortography in detecting ovarian artery collateral supply.

Amy M White1, Filip Banovac, Shadi Yousefi, Rebecca S Slack, James B Spies.   

Abstract

PURPOSE: To retrospectively determine the sensitivity of ovarian artery (OA) visualization at aortography performed after uterine fibroid embolization (UFE) and, using OA arteriography as the reference standard, compare the extent of arterial flow to the uterus at aortography with selective ovarian arteriography, to establish the utility of aortography and ovarian arteriography in the routine practice of UFE.
MATERIALS AND METHODS: This study received institutional review board approval with waiver of informed consent and was HIPAA compliant. Retrospective review of 1129 consecutive UFE patients (1072 with aortograms, 57 excluded; mean age, 44 years; range, 21-60 years) was performed to identify all visible OAs. Visible OAs were independently graded by two interventional radiologists according to extent of pelvic arterial flow. If selective arteriography was performed, a second grade was assigned based on assessment of the selective study. Descriptive and summary statistics were used for assessment by the senior observer, and interobserver variability was determined.
RESULTS: Of 1072 UFE patients, 184 (17.2%) had at least one visible OA. Ten (0.8%) patients were identified at aortography with collateral OA supply to more than 10% of the uterus. In total, 251 OAs were visualized, and 157 of these were further evaluated with selective study. Sixty-two (5.8%) patients were identified at selective arteriography as having collateral OA supply. The sensitivity of aortography was approximately 18%. Interobserver concordance was high (kappa values of 0.81 and 0.90 for aortography and selective study, respectively), but not perfect.
CONCLUSION: Aortography rarely helps identify patients with substantial residual OA supply to the uterus and is a poor predictor of the extent of that supply, and thus may be of limited utility in routine UFE. (c) RSNA, 2007.

Entities:  

Mesh:

Year:  2007        PMID: 17581907     DOI: 10.1148/radiol.2441060796

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  6 in total

1.  Determining the organ of origin of large pelvic masses in females using multidetector CT angiography and three-dimensional volume rendering CT angiography.

Authors:  YangKang Li; Yu Zheng; JunWei Chen; XueYin Chen; JianBang Lin; AiQun Cai; XiuGuo Zhou
Journal:  Eur Radiol       Date:  2014-11-02       Impact factor: 5.315

2.  Role of ovarian artery-to-uterine artery anastomoses in uterine artery embolization: initial anatomic and radiologic studies.

Authors:  Zhenbo Ouyang; Ping Liu; Yanhong Yu; Chunlin Chen; Xiaolei Song; Bo Liang; Guangming Zhong; Chang Liu; Zeyu Li
Journal:  Surg Radiol Anat       Date:  2011-10-19       Impact factor: 1.246

3.  Tumor feeding artery reconstruction with multislice spiral CT in the diagnosis of pelvic tumors of unknown origin.

Authors:  Hai-Jing Hu; Yong-Wen Huang; Ying-Chang Zhu
Journal:  Diagn Interv Radiol       Date:  2014 Jan-Feb       Impact factor: 2.630

4.  Primary postpartum hemorrhage: outcome of uterine artery embolization.

Authors:  Makoto Aoki; Hiroyuki Tokue; Masaya Miyazaki; Kei Shibuya; Satoshi Hirasawa; Kiyohiro Oshima
Journal:  Br J Radiol       Date:  2018-04-18       Impact factor: 3.039

5.  Characteristics of a New X-Ray Imaging System for Interventional Procedures: Improved Image Quality and Reduced Radiation Dose.

Authors:  Ruediger E Schernthaner; Reham R Haroun; Sonny Nguyen; Rafael Duran; Jae Ho Sohn; Sonia Sahu; Julius Chapiro; Yan Zhao; Alessandro Radaelli; Imramsjah M van der Bom; Maria Mauti; Kelvin Hong; Jean-François H Geschwind; MingDe Lin
Journal:  Cardiovasc Intervent Radiol       Date:  2017-10-31       Impact factor: 2.740

6.  Application of cone-beam computed tomography angiography in a uterine fibroid embolization procedure: A case report.

Authors:  F Alabdulghani; A O'Brien; D Brophy
Journal:  Radiol Case Rep       Date:  2017-10-27
  6 in total