Literature DB >> 17581798

Analysis of the second generation antidepressant venlafaxine and its main active metabolite O-desmethylvenlafaxine in human plasma by HPLC with spectrofluorimetric detection.

Roberto Mandrioli1, Laura Mercolini, Roberta Cesta, Salvatore Fanali, Mario Amore, Maria Augusta Raggi.   

Abstract

A high-performance liquid chromatographic method has been developed for the determination of the recent serotonin and norepinephrine reuptake inhibitor (SNRI) venlafaxine and its main active metabolite, O-desmethylvenlafaxine, in human plasma. Separation was obtained by using a reversed-phase column (C8, 150 x 4.6 mm I.D., 5 microm) and a mobile phase composed of 75% aqueous phosphate buffer containing triethylamine at pH 6.8 and 25% acetonitrile. Fluorescence detection was used, exciting at lambda=238 nm and monitoring the emission at lambda=300 nm. Citalopram was used as the internal standard. A careful pre-treatment of plasma samples was developed, using solid-phase extraction with C1 cartridges (100 mg, 1 mL). The limit of quantification (LOQ) was 1.0 ng mL(-1) and the limit of detection (LOD) was 0.3 ng mL(-1) for both analytes. The method was applied with success to plasma samples taken from patients undergoing treatment with venlafaxine. Precision data, as well as accuracy results, were satisfactory and no interference from other drugs was found. Hence, the method is suitable for therapeutic drug monitoring of venlafaxine and its main metabolite in depressed patients' plasma.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17581798     DOI: 10.1016/j.jchromb.2007.05.046

Source DB:  PubMed          Journal:  J Chromatogr B Analyt Technol Biomed Life Sci        ISSN: 1570-0232            Impact factor:   3.205


  3 in total

1.  Optimization and in vivo pharmacokinetic study of a novel controlled release venlafaxine hydrochloride three-layer tablet.

Authors:  Ahmed A Aboelwafa; Emad B Basalious
Journal:  AAPS PharmSciTech       Date:  2010-06-08       Impact factor: 3.246

2.  Development of an enantioselective assay for simultaneous separation of venlafaxine and O-desmethylvenlafaxine by micellar electrokinetic chromatography-tandem mass spectrometry: Application to the analysis of drug-drug interaction.

Authors:  Yijin Liu; Michael Jann; Chad Vandenberg; Chin B Eap; Shahab A Shamsi
Journal:  J Chromatogr A       Date:  2015-10-03       Impact factor: 4.759

3.  Development and validation of a rapid HPLC- fluorescence method for simultaneous determination of venlafaxine and its major metabolites in human plasma.

Authors:  Y H Ardakani; A Foroumadi; M R Rouini
Journal:  Daru       Date:  2010       Impact factor: 3.117