Discrepancies between catheter and Doppler estimates of aortic stenosis: the role of pressure recovery evaluated 'in vivo'.

Renato Razzolini1, Anna Manica, Giuseppe Tarantini, Angelo Ramondo, Massimo Napodano, Sabino Iliceto.   

Abstract

BACKGROUND AND AIM OF THE STUDY: Wide discrepancies are often observed between catheter- and Doppler-derived gradients and valve areas. The study aim was to verify if these measurements could be attenuated in a clinical setting by taking into account pressure recovery.
METHODS: Between 1st January 2000 and 31st March 2005, a total of 259 patients with an aortic valve area (AVA) < or =2 cm(2) was prospectively collected. During a standard diagnostic catheterization, the aortic valve gradient was taken as: [peak left ventricular pressure-- peak aortic pressure]. The AVA was calculated using the Gorlin formula (AG). Echocardiography was performed within 30 days of this procedure. Transvalvular gradients were measured using the Doppler technique, and the AVA was computed using the continuity equation (ACE). The diameter of the ascending aorta was monitored in the parasternal long-axis view, and the values averaged. The ascending aorta sectional area (AA) was then computed according to geometric formulae. In order to correct for pressure recovery, an energy loss coefficient (ELCO) equation was used [ELCO = (AA x ACE)/(AA -ACE)]. Correlations between AG, ACE and ELCO were evaluated by linear regression analysis. As cardiac output affects the estimates of valve areas, the correlation was calculated separately for patients with a median cardiac index (CI) above and below 2.7 1/min/m(2).
RESULTS: A good linear correlation was found between AG and ACE with regression coefficient 0.88, independent of cardiac output. A similar correlation was present between AG and ELCO, with correlation coefficient 0.99 in patients with CI >2.7 1/min/m(2), and

Entities:  

Mesh:

Year:  2007        PMID: 17578039

Source DB:  PubMed          Journal:  J Heart Valve Dis        ISSN: 0966-8519


  2 in total

1.  High transvalvular pressure gradients on intraoperative transesophageal echocardiography after aortic valve replacement: what does it mean?

Authors:  A Parnell; J Swanevelder
Journal:  HSR Proc Intensive Care Cardiovasc Anesth       Date:  2009

2.  Impact of energy loss index on left ventricular mass regression after aortic valve replacement.

Authors:  Terumasa Koyama; Hiroyuki Okura; Teruyoshi Kume; Kenzo Fukuhara; Koichiro Imai; Akihiro Hayashida; Yoji Neishi; Takahiro Kawamoto; Kazuo Tanemoto; Kiyoshi Yoshida
Journal:  J Echocardiogr       Date:  2013-11-26
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.