Literature DB >> 17576132

The use of Er:YAG laser for cavity preparation: an SEM evaluation.

Patricia Moreira Freitas1, Ricardo Scarparo Navarro, Juliana Almeida Barros, Carlos de Paula Eduardo.   

Abstract

OBJECTIVE: The purpose of this study was to evaluate morphological changes in cavities prepared by the Er:YAG laser (2.94 mum) at different parameters of irradiation and by a diamond bur. EXPERIMENTAL
DESIGN: Cavities were prepared on 27 human molars (n = 3): G1, 15 Hz/160 mJ enamel/6 Hz/200 mJ dentin; G2, 15 Hz/180 mJ enamel/6 Hz/200 mJ dentin; G3, 15 Hz/160 mJ enamel/6 Hz/250 mJ dentin; G4, 15 Hz/180 mJ enamel/6 Hz/250 mJ dentin; G5, 15 Hz/180 mJ enamel/10 Hz/180 mJ dentin; G6, 15 Hz/160 mJ enamel/10 Hz/180 mJ dentin; G7, 15 Hz/160 mJ enamel/10 Hz/160 mJ dentin; G8, 15 Hz/180 mJ enamel/10 Hz/160 mJ dentin; G9, diamond bur. For SEM analysis, samples were fixed (2.5% glutaraldheyde, 12 h, 4 degrees C), dehydrated (25-100% ethanol), dried, and sputter-coated with gold.
RESULTS: Despite the changes on energy and repetition-rate settings, all laser-treated samples showed no evidence of thermal damage or signs of burning and melting. Er:YAG laser ablated dental hard tissues showed exposed enamel prisms, dentin surface without smear layer, and opened dentinal tubules.
CONCLUSION: Different Er:YAG laser parameters were effective for ablation of hard tissues, creating an irregular and microretentive morphological pattern without hard tissue damage.

Entities:  

Mesh:

Year:  2007        PMID: 17576132     DOI: 10.1002/jemt.20470

Source DB:  PubMed          Journal:  Microsc Res Tech        ISSN: 1059-910X            Impact factor:   2.769


  29 in total

1.  Scanning electron microscopy study of cavity preparation in deciduous teeth using the Er:YAG laser with different powers.

Authors:  Sun Zhang; Tao Chen; Li-hong Ge
Journal:  Lasers Med Sci       Date:  2010-11-11       Impact factor: 3.161

2.  Evaluation of the Morphological Characteristics of Laser-Irradiated Dentin.

Authors:  Barbara Cvikl; Bledar Lilaj; Alexander Franz; Daniela Degendorfer; Andreas Moritz
Journal:  Photomed Laser Surg       Date:  2015-09-21       Impact factor: 2.796

3.  Composite filling removal with erbium:yttrium-aluminum-garnet laser: morphological analyses.

Authors:  Alessandra M Correa-Afonso; Regina G Palma-Dibb; Jesus Djalma Pécora
Journal:  Lasers Med Sci       Date:  2008-07-04       Impact factor: 3.161

4.  Shear bond strength and ultrastructural interface analysis of different adhesive systems to Er:YAG laser-prepared dentin.

Authors:  Yeliz Guven; Oya Aktoren
Journal:  Lasers Med Sci       Date:  2013-08-28       Impact factor: 3.161

5.  Role of surface tension and roughness on the wettability of Er:YAG laser irradiated dentin: In vitro study.

Authors:  Nathalie Brulat; Carlo Fornaini; Jean-Paul Rocca; Evelyne Darque-Ceretti
Journal:  Laser Ther       Date:  2013

6.  Use of the erbium, chromium:yttrium-scandium-gallium-garnet laser on human enamel tissues. Influence of the air-water spray on the laser-tissue interaction: scanning electron microscope evaluations.

Authors:  Giovanni Olivi; Francesca Angiero; Stefano Benedicenti; Giuseppe Iaria; Antonio Signore; Vassilios Kaitsas
Journal:  Lasers Med Sci       Date:  2009-06-23       Impact factor: 3.161

7.  The effect of different enamel surface treatments on the microleakage of fissure sealants.

Authors:  Ozgul Baygin; Fatih Mehmet Korkmaz; Tamer Tüzüner; Mehmet Tanriver
Journal:  Lasers Med Sci       Date:  2011-04-08       Impact factor: 3.161

8.  Micromorphology and adhesive performance of Er:YAG laser-treated dentin of primary teeth.

Authors:  Simon Flury; Tamara Koch; Anne Peutzfeldt; Adrian Lussi
Journal:  Lasers Med Sci       Date:  2011-02-05       Impact factor: 3.161

9.  A three-dimensional evaluation of microleakage of class V cavities prepared by the very short pulse mode of the erbium:yttrium-aluminium-garnet laser.

Authors:  Silvana Jukić Krmek; Ivana Bogdan; Paris Simeon; Goranka Prpić Mehicić; Davor Katanec; Ivica Anić
Journal:  Lasers Med Sci       Date:  2009-07-11       Impact factor: 3.161

10.  The evaluation of the vector system in removal of carious tissue.

Authors:  Mine Yildirim; Figen Seymen; Nurullah Keklikoglu
Journal:  Int J Dent       Date:  2010-04-29
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.