Literature DB >> 17571987

Comparison of three methods of temperature measurement in hypothermic, euthermic, and hyperthermic dogs.

Rebecca J Greer1, Leah A Cohn, John R Dodam, Colette C Wagner-Mann, F A Mann.   

Abstract

OBJECTIVE: To assess the reliability and accuracy of a predictive rectal thermometer, an infrared auricular thermometer designed for veterinary use, and a subcutaneous temperature-sensing microchip for measurement of core body temperature over various temperature conditions in dogs.
DESIGN: Prospective study. ANIMALS: 8 purpose-bred dogs. PROCEDURES: A minimum of 7 days prior to study commencement, a subcutaneous temperature-sensing microchip was implanted in 1 of 3 locations (interscapular, lateral aspect of shoulder, or sacral region) in each dog. For comparison with temperatures measured via rectal thermometer, infrared auricular thermometer, and microchip, core body temperature was measured via a thermistor-tipped pulmonary artery (TTPA) catheter. Hypothermia was induced during anesthesia at the time of TTPA catheter placement; on 3 occasions after placement of the catheter, hyperthermia was induced via administration of a low dose of endotoxin. Near-simultaneous duplicate temperature measurements were recorded from the TTPA catheter, the rectal thermometer, auricular thermometer, and subcutaneous microchips during hypothermia, euthermia, and hyperthermia. Reliability (variability) of temperature measurement for each device and agreement between each device measurement and core body temperature were assessed.
RESULTS: Variability between duplicate near-simultaneous temperature measurements was greatest for the auricular thermometer and least for the TTPA catheter. Measurements obtained by use of the rectal thermometer were in closest agreement with core body temperature; for all other devices, temperature readings typically underestimated core body temperature. CONCLUSIONS AND CLINICAL RELEVANCE: Among the 3 methods of temperature measurement, rectal thermometry provided the most accurate estimation of core body temperature in dogs.

Entities:  

Mesh:

Year:  2007        PMID: 17571987     DOI: 10.2460/javma.230.12.1841

Source DB:  PubMed          Journal:  J Am Vet Med Assoc        ISSN: 0003-1488            Impact factor:   1.936


  15 in total

1.  Comparison of digital rectal and microchip transponder thermometry in cats.

Authors:  Jessica M Quimby; Francisco Olea-Popelka; Michael R Lappin
Journal:  J Am Assoc Lab Anim Sci       Date:  2009-07       Impact factor: 1.232

2.  Comparison between auricular and standard rectal thermometers for the measurement of body temperature in dogs.

Authors:  Marlos G Sousa; Roberta Carareto; Valdo A Pereira-Junior; Monally C C Aquino
Journal:  Can Vet J       Date:  2011-04       Impact factor: 1.008

3.  Comparison between core temperatures measured telemetrically using the CorTemp® ingestible temperature sensor and rectal temperature in healthy Labrador retrievers.

Authors:  Stephanie Osinchuk; Susan M Taylor; Cindy L Shmon; John Pharr; John Campbell
Journal:  Can Vet J       Date:  2014-10       Impact factor: 1.008

4.  Activation of NPRs and UCP1-independent pathway following CB1R antagonist treatment is associated with adipose tissue beiging in fat-fed male dogs.

Authors:  Malini S Iyer; Rebecca L Paszkiewicz; Richard N Bergman; Joyce M Richey; Orison O Woolcott; Isaac Asare-Bediako; Qiang Wu; Stella P Kim; Darko Stefanovski; Cathryn M Kolka; Deborah J Clegg; Morvarid Kabir
Journal:  Am J Physiol Endocrinol Metab       Date:  2019-06-25       Impact factor: 4.310

5.  Effect of intravenous fluid warming on core body temperature during elective orthopedic procedures.

Authors:  Robert B E Brady; William T Poppell
Journal:  Can Vet J       Date:  2020-10       Impact factor: 1.008

6.  Effects of environmental condition, size, coat type, and body condition score on rectal temperature prediction in dogs using infrared auricular and surface temperature.

Authors:  Yanisa Lukkanawaraporn; Nutnicha Tiangtas; Vorapan Chaikornkij; Patthamon Nawapakpilai; Sathita Areerat; Pipatpong Chundang; Chalermpol Lekcharoensuk; Attawit Kovitvadhi
Journal:  Vet World       Date:  2022-05-25

7.  Short Communication: Use of Infrared Thermometers for Cutaneous Temperature Recording: Agreement with the Rectal Temperature in Felis catus.

Authors:  Claudia Giannetto; Giuseppe Acri; Melissa Pennisi; Giuseppe Piccione; Francesca Arfuso; Annastella Falcone; Elisabetta Giudice; Simona Di Pietro
Journal:  Animals (Basel)       Date:  2022-05-16       Impact factor: 3.231

8.  Comparison of noncontact infrared thermometry and 3 commercial subcutaneous temperature transponding microchips with rectal thermometry in rhesus macaques (Macaca mulatta).

Authors:  Marla K Brunell
Journal:  J Am Assoc Lab Anim Sci       Date:  2012-07       Impact factor: 1.232

9.  Comparison of Microchip Transponder and Noncontact Infrared Thermometry with Rectal Thermometry in Domestic Swine (Sus scrofa domestica).

Authors:  Amanda L Jara; Jarod M Hanson; Jon D Gabbard; Scott K Johnson; Emery T Register; Biao He; S Mark Tompkins
Journal:  J Am Assoc Lab Anim Sci       Date:  2016       Impact factor: 1.232

10.  The accuracy of tactile assessment of canine nose temperature to identify rectal hyperthermia and hypothermia in dogs presenting on an emergency basis.

Authors:  Christopher R Kennedy; Jonathan M Babyak; Elizabeth A Rozanski
Journal:  Can J Vet Res       Date:  2021-07       Impact factor: 1.310

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.