Literature DB >> 17570495

Development and evaluation of intermediate frequency magnetic field exposure system for studies of in vitro biological effects.

Atsushi Fujita1, Izuo Hirota, Yoshinobu Kawahara, Hideki Omori.   

Abstract

We have developed an intermediate frequency (IF) magnetic field exposure system for in vitro studies. Since there are no previous studies on exposure to heating-frequency magnetic fields generated from an induction heating (IH) cook top, there is a strong need for such an exposure system and for biological studies of IF magnetic fields. This system mainly consists of a magnetic-field-generating coil housed inside an incubator, inside which cultured cells can be exposed to magnetic field. Two systems were prepared to allow the experiment to be conducted in a double-blind manner. The level of the generated magnetic field was set to 532 microT rms in the exposure space, 23 kHz, 80 times the value in the International Commission on Non-ionizing Radiation Protection (ICNIRP) guidelines, with a spatial field uniformity better than 3.8%. The waveforms were nearly sinusoidal. It was also confirmed that the parasitic electric field was 157 V/m rms and the induced electric field was 1.9 V/m rms. The temperature was maintained at 36.5 +/- 0.5 degrees C for 2 h. Furthermore, leaked magnetic flux density was 0.7 microT rms or lower at extremely low frequency (ELF) and IF in the stopped system when the other system was being operated, and the environmental magnetic flux density was 0.1 microT rms or lower at the center of the coils. As a result, it was confirmed that this system could be successfully used to evaluate the biological effects of exposure to IF magnetic fields.

Entities:  

Mesh:

Year:  2007        PMID: 17570495     DOI: 10.1002/bem.20339

Source DB:  PubMed          Journal:  Bioelectromagnetics        ISSN: 0197-8462            Impact factor:   2.010


  3 in total

1.  Lack of teratological effects in rats exposed to 20 or 60 kHz magnetic fields.

Authors:  Izumi Nishimura; Atsushi Oshima; Kazumoto Shibuya; Tadashi Negishi
Journal:  Birth Defects Res B Dev Reprod Toxicol       Date:  2011-07-18

2.  Acute and subchronic toxicity of 20  kHz and 60  kHz magnetic fields in rats.

Authors:  Izumi Nishimura; Atsushi Oshima; Kazumoto Shibuya; Takashi Mitani; Tadashi Negishi
Journal:  J Appl Toxicol       Date:  2015-05-17       Impact factor: 3.446

3.  Measurement of Intermediate Frequency Magnetic Fields Generated by Household Induction Cookers for Epidemiological Studies and Development of an Exposure Estimation Model.

Authors:  Takumi Kitajima; Joachim Schüz; Akemi Morita; Wakaha Ikeda; Hirokazu Tanaka; Kayo Togawa; Esteban C Gabazza; Masao Taki; Kuniaki Toriyabe; Tomoaki Ikeda; Shigeru Sokejima
Journal:  Int J Environ Res Public Health       Date:  2022-09-21       Impact factor: 4.614

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.