Literature DB >> 17568842

The influence of 2 condensation techniques on the marginal seal of packable resin composite restorations.

Ariel Ben-Amar1, Hagay Slutzky, Shlomo Matalon.   

Abstract

OBJECTIVE: To evaluate the effect of manual condensation versus a combination of manual and mechanical, or automatic, condensation on the gingival marginal seal of packable resin composite restorations. METHOD AND MATERIALS: Two packable composites, Pyramid Dentin (Bisco Dental) and Filtek P-60 (3M Espe), were tested. The study consisted of 37 extracted caries-free human molars and premolars. In each tooth, 2 standardized Class 2 cavities were prepared and restored using the incremental technique; the mesial restoration was condensed by hand instrument, and the distal by a combination of the manual and mechanical condenser (KaVo). Restored teeth were subjected to automatic thermal stresses and cycling load stresses. Teeth were immersed in 0.5% basic fuchsin at 37 degrees C for 96 hours. Samples were sectioned mesiodistally in 3 sections. Dye penetration at the gingival margin was examined.
RESULTS: Automatic condensation of Filtek P-60 and Pyramid demonstrated better sealing properties, with a median dye penetration of 0 and 1, respectively (on a dye penetration scale of 0 to 3), compared to manual condensation, median of 2 (P = .043) and 3 (P = .079), respectively. Better sealing ability was shown with P-60 than with Pyramid Dentin when manual condensation was used (P = .037). No significant difference was observed between the 2 products when tested with automatic condensation (P = .066).
CONCLUSION: In this in vitro study the combination of manual and automatic condensation resulted in reduced gingival margin microleakage for both packable composites.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17568842

Source DB:  PubMed          Journal:  Quintessence Int        ISSN: 0033-6572            Impact factor:   1.677


  2 in total

1.  Evaluation of marginal integrity of four bulk-fill dental composite materials: in vitro study.

Authors:  Mirosław Orłowski; Bożena Tarczydło; Renata Chałas
Journal:  ScientificWorldJournal       Date:  2015-03-22

2.  Comparing marginal microleakage of three Bulk Fill composites in Class II cavities using confocal microscope: An in vitro study.

Authors:  Manne Udaya Swapna; Sunil Koshy; Arvind Kumar; Naveen Nanjappa; Shiny Benjamin; Mohan Thomas Nainan
Journal:  J Conserv Dent       Date:  2015 Sep-Oct
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.