Literature DB >> 17568545

In vivo EBT radiochromic film dosimetry of electron beam for Total Skin Electron Therapy (TSET).

A Bufacchi1, A Carosi, N Adorante, S Delle Canne, T Malatesta, R Capparella, R Fragomeni, A Bonanni, M Leone, L Marmiroli, L Begnozzi.   

Abstract

EBT radiochromic films were used to determine skin-dose maps for patients undergone Total Skin Electron Therapy (TSET). Gafchromic EBT radiochromic film is one of the newest radiation-induced auto-developing photon and electron-beam analysis films available for therapeutic radiation dosimetry in radiotherapy applications. EBT films can be particularly useful in TSET; due to patient morphology, underdosed regions typically occur, and the radiochromic film represents a suitable candidate for monitoring them. In this study, TSET was applied to treat cutaneous T-cell lymphoma. The technique for TSET was implemented by using an electron beam with a nominal energy of 6MeV. The patient was treated in a standing position using dual angled fields in order to obtain the greatest dose uniformity along the patient's longitudinal axis. The electron beam energy was degraded by a PMMA filter. The in vivo dose distribution was determined through the use of EBT films, as well as of thermoluminescent dosimeters for comparison (TLDs). EBT results showed a reasonable agreement with TLDs data.

Entities:  

Mesh:

Year:  2007        PMID: 17568545     DOI: 10.1016/j.ejmp.2007.03.003

Source DB:  PubMed          Journal:  Phys Med        ISSN: 1120-1797            Impact factor:   2.685


  6 in total

Review 1.  Review of the results of the in vivo dosimetry during total skin electron beam therapy.

Authors:  Gabriele Guidi; Giovanni Gottardi; Paola Ceroni; Tiziana Costi
Journal:  Rep Pract Oncol Radiother       Date:  2013-08-15

2.  Cherenkov imaging for total skin electron therapy (TSET).

Authors:  Yunhe Xie; Heather Petroccia; Amit Maity; Tianshun Miao; Yihua Zhu; Petr Bruza; Brian W Pogue; John P Plastaras; Lei Dong; Timothy C Zhu
Journal:  Med Phys       Date:  2019-11-26       Impact factor: 4.071

3.  Measurement and comparison of skin dose using OneDose MOSFET and Mobile MOSFET for patients with acute lymphoblastic leukemia.

Authors:  Essam H Mattar; Lina F Hammad; Huda I Al-Mohammed
Journal:  Med Sci Monit       Date:  2011-07

4.  Evaluation of clinical use of OneDose metal oxide semiconductor field-effect transistor detectors compared to thermoluminescent dosimeters to measure skin dose for adult patients with acute lymphoblastic leukemia.

Authors:  Huda Ibrahim Al-Mohammed
Journal:  N Am J Med Sci       Date:  2011-08

5.  Evaluation of the uncertainty in an EBT3 film dosimetry system utilizing net optical density.

Authors:  Elsa Y León Marroquin; José A Herrera González; Miguel A Camacho López; José E Villarreal Barajas; Olivia A García-Garduño
Journal:  J Appl Clin Med Phys       Date:  2016-09-08       Impact factor: 2.102

6.  Monte Carlo simulations of EBT3 film dose deposition for percentage depth dose (PDD) curve evaluation.

Authors:  Spencer M Robinson; Nolan Esplen; Derek Wells; Magdalena Bazalova-Carter
Journal:  J Appl Clin Med Phys       Date:  2020-11-06       Impact factor: 2.102

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.