Literature DB >> 17566984

Detection of cardiac biomarkers using micellar electrokinetic chromatography and a cleavable tag immunoassay.

Meghan M Caulum1, Brian M Murphy, Lauren M Ramsay, Charles S Henry.   

Abstract

Biomarkers provide clinicians with an important tool for disease assessment. Many different biomarkers have been discovered, but few of them suffice as stand-alone indicators for disease presence or prognosis. Because no single biomarker can be relied upon for accurate disease detection there has been a substantial push for new multianalyte screening methods. Furthermore, there is a need to push assays toward a point-of-care technology to reduce the time between clinical analysis and medical intervention and minimize artifacts created during sample storage. There currently are, however, few inexpensive multianalyte methods for disease detection that can function in a point-of-care setting. A new approach which bridges the gap between traditional immunoassays and high-density microarrays by utilizing microfluidics, immunoassays, and micellar electrokinetic chromatography (MEKC) is discussed here. This chemistry, the cleavable tag immunoassay (CTI), is a low- to medium-density heterogeneous immunoassay designed to detect 1-20 analytes simultaneously. Although similar to traditional sandwich immunoassays, this approach is unique because the signal is not imaged on the surface; instead, a fluorescent tag is chemically cleaved from the antibody and analyzed by microchip MEKC. In this report, the CTI chemistry is used for the detection of four cardiac biomarkers elevated in acute myocardial infarction. Limit of detection (LOD) and dynamic range are reported for all biomarkers with LODs on the order of low nanograms per milliliter to low picograms per milliliter. Most importantly, the dynamic range for each of the biomarkers spans the boundary between normal and elevated levels. Finally, elevated marker levels were measured in spiked human serum samples.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17566984     DOI: 10.1021/ac070452v

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  6 in total

1.  Preconcentration and detection of the phosphorylated forms of cardiac troponin I in a cascade microchip by cationic isotachophoresis.

Authors:  Danny Bottenus; Mohammad Robiul Hossan; Yexin Ouyang; Wen-Ji Dong; Prashanta Dutta; Cornelius F Ivory
Journal:  Lab Chip       Date:  2011-09-21       Impact factor: 6.799

2.  Multiplexing Fluorescence Anisotropy Using Frequency Encoding.

Authors:  Adrian M Schrell; Nikita Mukhitov; Michael G Roper
Journal:  Anal Chem       Date:  2016-08-02       Impact factor: 6.986

Review 3.  Affinity assays for detection of cellular communication and biomarkers.

Authors:  Christelle Guillo; Michael G Roper
Journal:  Analyst       Date:  2008-10-02       Impact factor: 4.616

4.  Sensitive Detection of Cardiac Biomarkers Using a Magnetic Microbead Immunoassay.

Authors:  Christine F Woolley; Mark A Hayes
Journal:  Anal Methods       Date:  2015-08-20       Impact factor: 2.896

Review 5.  New technologies in affinity assays to explore biological communication.

Authors:  Michael G Roper; Christelle Guillo
Journal:  Anal Bioanal Chem       Date:  2008-08-31       Impact factor: 4.142

6.  Detection of cardiac biomarkers using single polyaniline nanowire-based conductometric biosensors.

Authors:  Innam Lee; Xiliang Luo; Jiyong Huang; Xinyan Tracy Cui; Minhee Yun
Journal:  Biosensors (Basel)       Date:  2012-05-14
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.