Literature DB >> 1756555

Morphologic change in coronary artery stenosis with the Medtronic Wiktor stent: initial results from the core laboratory for quantitative angiography.

P Serruys1, P De Jaegere, M Bertrand, G Kober, J F Marquis, J Piessens, R Uebis, B Valeix, V Wiegand.   

Abstract

The purpose of this study was to assess the early changes in stenosis geometry after implantation of the Medtronic Wiktor stent in human coronary arteries. Morphologic changes were evaluated by quantitative coronary angiography using automated edge detection. The hemodynamic significance of the morphologic changes were assessed by the calculation of the theoretical pressure drop across the dilated and stented stenosis derived from the Poiseuile and turbulent resistances assuming a coronary blood flow of either 0.5, 1, or 3 ml/sec. Fifty patients were studied before and immediately after stent implantation. The stented coronary artery was the left anterior descending artery in 26 patients, the circumflex artery in eight patients, and the right coronary artery in 16 patients. Stent implantation resulted in an additional increase in the minimal luminal cross-sectional area and minimal luminal diameter of the dilated vessel without changing the curvature of the stenosis. Furthermore, there was a significant reduction of the "plaque area." This was associated with a normalization of the calculated resistances to flow and pressure drop across the stenosis. To a minimal extent, recoil (0.1 +/- 0.36 mm) was observed after stent implantation.

Entities:  

Mesh:

Year:  1991        PMID: 1756555     DOI: 10.1002/ccd.1810240403

Source DB:  PubMed          Journal:  Cathet Cardiovasc Diagn        ISSN: 0098-6569


  3 in total

Review 1.  Endovascular stents: a 'break through technology', future challenges.

Authors:  A G Violaris; Y Ozaki; P W Serruys
Journal:  Int J Card Imaging       Date:  1997-02

2.  Predictors of acute scaffold recoil after implantation of the everolimus-eluting bioresorbable scaffold: an optical coherence tomography assessment in native coronary arteries.

Authors:  Takao Sato; John Jose; Mohamed El-Mawardy; Dmitriy S Sulimov; Ralph Tölg; Gert Richardt; Mohamed Abdel-Wahab
Journal:  Int J Cardiovasc Imaging       Date:  2016-10-19       Impact factor: 2.357

3.  In vivo assessment of stent recoil of biodegradable polymer-coated cobalt-chromium sirolimus-eluting coronary stent system.

Authors:  Atul D Abhyankar; Ashok S Thakkar
Journal:  Indian Heart J       Date:  2012-07-27
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.