Role of environmental surveillance in determining the risk of hospital-acquired legionellosis: a national surveillance study with clinical correlations.

Janet E Stout1, Robert R Muder, Sue Mietzner, Marilyn M Wagener, Mary Beth Perri, Kathleen DeRoos, Dona Goodrich, William Arnold, Theresa Williamson, Ola Ruark, Christine Treadway, Elizabeth C Eckstein, Debra Marshall, Mary Ellen Rafferty, Kathleen Sarro, Joann Page, Robert Jenkins, Gina Oda, Kathleen J Shimoda, Marcus J Zervos, Marvin Bittner, Sharon L Camhi, Anand P Panwalker, Curtis J Donskey, Minh-Hong Nguyen, Mark Holodniy, Victor L Yu.   

Abstract

OBJECTIVE: Hospital-acquired Legionella pneumonia has a fatality rate of 28%, and the source is the water distribution system. Two prevention strategies have been advocated. One approach to prevention is clinical surveillance for disease without routine environmental monitoring. Another approach recommends environmental monitoring even in the absence of known cases of Legionella pneumonia. We determined the Legionella colonization status of water systems in hospitals to establish whether the results of environmental surveillance correlated with discovery of disease. None of these hospitals had previously experienced endemic hospital-acquired Legionella pneumonia.
DESIGN: Cohort study.
SETTING: Twenty US hospitals in 13 states.
INTERVENTIONS: Hospitals performed clinical and environmental surveillance for Legionella from 2000 through 2002. All specimens were shipped to the Special Pathogens Laboratory at the Veterans Affairs Pittsburgh Medical Center.
RESULTS: Legionella pneumophila and Legionella anisa were isolated from 14 (70%) of 20 hospital water systems. Of 676 environmental samples, 198 (29%) were positive for Legionella species. High-level colonization of the water system (30% or more of the distal outlets were positive for L. pneumophila) was demonstrated for 6 (43%) of the 14 hospitals with positive findings. L. pneumophila serogroup 1 was detected in 5 of these 6 hospitals, whereas 1 hospital was colonized with L. pneumophila serogroup 5. A total of 633 patients were evaluated for Legionella pneumonia from 12 (60%) of the 20 hospitals: 377 by urinary antigen testing and 577 by sputum culture. Hospital-acquired Legionella pneumonia was identified in 4 hospitals, all of which were hospitals with L. pneumophila serogroup 1 found in 30% or more of the distal outlets. No cases of disease due to other serogroups or species (L. anisa) were identified.
CONCLUSION: Environmental monitoring followed by clinical surveillance was successful in uncovering previously unrecognized cases of hospital-acquired Legionella pneumonia.

Entities:  

Mesh:

Year:  2007        PMID: 17564984     DOI: 10.1086/518754

Source DB:  PubMed          Journal:  Infect Control Hosp Epidemiol        ISSN: 0899-823X            Impact factor:   3.254


  25 in total

1.  Happy new fear: new disease of the year.

Authors:  Karmen Loncarek
Journal:  Croat Med J       Date:  2009-06       Impact factor: 1.351

Review 2.  The role of water in healthcare-associated infections.

Authors:  Brooke K Decker; Tara N Palmore
Journal:  Curr Opin Infect Dis       Date:  2013-08       Impact factor: 4.915

3.  Guidelines for preventing infectious complications among hematopoietic cell transplantation recipients: a global perspective.

Authors:  Marcie Tomblyn; Tom Chiller; Hermann Einsele; Ronald Gress; Kent Sepkowitz; Jan Storek; John R Wingard; Jo-Anne H Young; Michael J Boeckh; Michael A Boeckh
Journal:  Biol Blood Marrow Transplant       Date:  2009-10       Impact factor: 5.742

4.  Detection of legionella contamination in tabriz hospitals by PCR assay.

Authors:  Reza Ghotaslou; Fatemeh Yeganeh Sefidan; Mohammad Taghi Akhi; Mohammad Hussein Soroush; Mohammad Saeid Hejazi
Journal:  Adv Pharm Bull       Date:  2013-02-07

5.  Legionellosis in Transplantation.

Authors:  Shobini Sivagnanam; Steven A Pergam
Journal:  Curr Infect Dis Rep       Date:  2016-03       Impact factor: 3.725

6.  Functional type 1 secretion system involved in Legionella pneumophila virulence.

Authors:  Fabien Fuche; Anne Vianney; Claire Andrea; Patricia Doublet; Christophe Gilbert
Journal:  J Bacteriol       Date:  2014-11-24       Impact factor: 3.490

7.  Prevalence of Infection-Competent Serogroup 6 Legionella pneumophila within Premise Plumbing in Southeast Michigan.

Authors:  Brenda G Byrne; Sarah McColm; Shawn P McElmurry; Paul E Kilgore; Joanne Sobeck; Rick Sadler; Nancy G Love; Michele S Swanson
Journal:  MBio       Date:  2018-02-06       Impact factor: 7.867

8.  A comprehensive evaluation of monochloramine disinfection on water quality, Legionella and other important microorganisms in a hospital.

Authors:  Darren A Lytle; Stacy Pfaller; Christy Muhlen; Ian Struewing; Simoni Triantafyllidou; Colin White; Sam Hayes; Dawn King; Jingrang Lu
Journal:  Water Res       Date:  2020-11-18       Impact factor: 11.236

9.  Contamination of Hospital Water Supplies in Gilan, Iran, with Legionella pneumophila, Escherichia coli, and Pseudomonas aeruginosa.

Authors:  Masoumeh Ahmadi Jalali Moghadam; Hamidreza Honarmand; Sajad Asfaram Meshginshahr
Journal:  Interdiscip Perspect Infect Dis       Date:  2015-09-07

10.  Combination of Heat Shock and Enhanced Thermal Regime to Control the Growth of a Persistent Legionella pneumophila Strain.

Authors:  Emilie Bédard; Inès Boppe; Serge Kouamé; Philippe Martin; Linda Pinsonneault; Louis Valiquette; Jules Racine; Michèle Prévost
Journal:  Pathogens       Date:  2016-04-15
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.