Literature DB >> 17560379

Polychlorinated biphenyls (PCBs) detection in milk samples by an electrochemical magneto-immunosensor (EMI) coupled to solid-phase extraction (SPE) and disposable low-density arrays.

S Centi1, E Silva, S Laschi, I Palchetti, M Mascini.   

Abstract

An electrochemical immunosensor for polychlorinated biphenyl (PCB) detection based on graphite screen-printed low-density arrays and on magnetic beads is reported. The immunological reaction for the detection of PCBs is based on a direct competitive assay using alkaline phosphatase (AP) as enzymatic label. After the immunochemical recognition, the modified magnetic beads are captured by a magnet on the surface of the graphite working electrode. The electrochemical detection is thus achieved through the addition of the AP substrate (alpha-naphthyl-phosphate). Two different antibodies (sIgG anti-PCB28 and rIgG anti-PCB77) were tested and compared in terms of sensitivity and ability to recognise different congeners. The developed electrochemical magneto-immunosensor (EMI) was successfully combined with solid-phase extraction (SPE) for the analysis of PCBs in milk samples. In spiked samples a recovery of 80% was obtained. The proposed strategy offers great promise for rapid, simple, cost-effective, and on-site analysis of clinical, food and environmental samples, considering also that low-density arrays allow the simultaneous analysis of different processed samples.

Entities:  

Year:  2007        PMID: 17560379     DOI: 10.1016/j.aca.2007.04.064

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  3 in total

Review 1.  The need and potential of biosensors to detect dioxins and dioxin-like polychlorinated biphenyls along the milk, eggs and meat food chain.

Authors:  Jeerasak Chobtang; Imke J M de Boer; Ron L A P Hoogenboom; Willem Haasnoot; Aize Kijlstra; Bastiaan G Meerburg
Journal:  Sensors (Basel)       Date:  2011-12-15       Impact factor: 3.576

2.  DNA-Based Sensor for the Detection of an Organophosphorus Pesticide: Profenofos.

Authors:  Giulia Selvolini; Ioana Băjan; Oana Hosu; Cecilia Cristea; Robert Săndulescu; Giovanna Marrazza
Journal:  Sensors (Basel)       Date:  2018-06-25       Impact factor: 3.576

Review 3.  Trends and Perspectives in Immunosensors for Determination of Currently-Used Pesticides: The Case of Glyphosate, Organophosphates, and Neonicotinoids.

Authors:  Eduardo C Reynoso; Eduardo Torres; Francesca Bettazzi; Ilaria Palchetti
Journal:  Biosensors (Basel)       Date:  2019-02-04
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.