Literature DB >> 17560178

Liquid chromatography/negative ion electrospray tandem mass spectrometry method for the quantification of rosuvastatin in human plasma: application to a pharmacokinetic study.

Jun Gao1, Dafang Zhong, Xiaotao Duan, Xiaoyan Chen.   

Abstract

A sensitive liquid chromatography/tandem mass spectrometric (LC-MS/MS) method was developed and validated for the determination of rosuvastatin in human plasma. The plasma samples were prepared using liquid-liquid extraction with ethyl ether. Chromatographic separation was accomplished on a Zorbax XDB-C18 (150 mm x 4.6 mm i.d., 5 microm) column. The mobile phase consisted of methanol-water (75:25, v/v, adjusted to pH 6 by aqueous ammonia). Detection of rosuvastatin and the internal standard (IS) hydrochlorothiazide was achieved by ESI MS/MS in the negative ion mode. The lower limit of quantification was 0.020 ng/ml by using 200 microl aliquots of plasma. The linear range of the method was from 0.020 to 60.0 ng/ml. The intra- and inter-day precisions were lower than 8.5% in terms of relative standard deviation (RSD), and the accuracy was within -0.3 to 1.9% in terms of relative error (RE). Compared with the existing methods, the validated method offered increased sensitivity. The method was successfully applied for the evaluation of pharmacokinetics of rosuvastatin after single oral doses of 5, 10 and 20 mg rosuvastatin to 10 healthy volunteers.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17560178     DOI: 10.1016/j.jchromb.2007.05.012

Source DB:  PubMed          Journal:  J Chromatogr B Analyt Technol Biomed Life Sci        ISSN: 1570-0232            Impact factor:   3.205


  8 in total

1.  Severe rosuvastatin accumulation with rhabdomyolysis due to drug interactions and low cardiac output syndrome.

Authors:  Marco Previsdomini; Elisa Graziano; Laurent Decosterd; Perrine Courlet; Andreas Perren; Alessandro Ceschi
Journal:  Br J Clin Pharmacol       Date:  2019-05-03       Impact factor: 4.335

2.  Magnetic nanoparticles modified with organic dendrimers containing methyl methacrylate and ethylene diamine for the microextraction of rosuvastatin.

Authors:  Heman Mirzapour; Homayon Ahmad Panahi; Elham Moniri; Alireza Feizbakhsh
Journal:  Mikrochim Acta       Date:  2018-09-01       Impact factor: 5.833

3.  Generation of polyclonal antibody with high avidity to rosuvastatin and its use in development of highly sensitive ELISA for determination of rosuvastatin in plasma.

Authors:  Ibrahim A Darwish; Abdul-Rahman M Al-Obaid; Hamoud A Al-Malaq
Journal:  Chem Cent J       Date:  2011-07-05       Impact factor: 4.215

4.  Development and Validation of a Stability-Indicating RP-UPLC Method for Determination of Rosuvastatin and Related Substances in Pharmaceutical Dosage Form.

Authors:  Harshal Kanubhai Trivedi; Mukesh C Patel
Journal:  Sci Pharm       Date:  2012-03-26

5.  Development, validation of liquid chromatography-tandem mass spectrometry method for simultaneous determination of rosuvastatin and metformin in human plasma and its application to a pharmacokinetic study.

Authors:  P Pavan Kumar; T E G K Murthy; M V Basaveswara Rao
Journal:  J Adv Pharm Technol Res       Date:  2015 Jul-Sep

6.  A New Oleanolic Acid Derivative against CCl₄-Induced Hepatic Fibrosis in Rats.

Authors:  Hongjun Xiang; Yaotian Han; Yuzhong Zhang; Wenqiang Yan; Bing Xu; Fuhao Chu; Tianxin Xie; Menglu Jia; Mengmeng Yan; Rui Zhao; Penglong Wang; Haimin Lei
Journal:  Int J Mol Sci       Date:  2017-03-06       Impact factor: 5.923

7.  Hydrophilic Interaction Liquid Chromatography-Electrospray Ionization Mass Spectrometry for Therapeutic Drug Monitoring of Metformin and Rosuvastatin in Human Plasma.

Authors:  Nikolaos Antonopoulos; Giorgos Machairas; George Migias; Ariadni Vonaparti; Vasiliki Brakoulia; Constantinos Pistos; Dimitra Gennimata; Irene Panderi
Journal:  Molecules       Date:  2018-06-27       Impact factor: 4.411

8.  Simultaneous determination of rosuvastatin and amlodipine in human plasma using tandem mass spectrometry: Application to disposition kinetics.

Authors:  Anjaneyulu Narapusetti; Syama Sundar Bethanabhatla; Anbazhagan Sockalingam; Nagakishore Repaka; Veldandi Saritha
Journal:  J Adv Res       Date:  2014-09-06       Impact factor: 10.479

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.