Literature DB >> 17559618

The effect of core framework designs on the fracture loads of all-ceramic fixed partial dentures on posterior implants.

Y Kokubo1, M Tsumita, S Sakurai, K Torizuka, P Vult von Steyern, S Fukushima.   

Abstract

This study evaluated the fracture loads of three-unit all-ceramic bridges on implants; the core frameworks of the bridges were made of zirconium oxide. Three core framework designs were fabricated according to the design of the bars between the retainers: (i) straight, (ii) curved in the occlusal direction, or (iii) curved in the gingival direction. A static load was applied at the centre of the pontic, and the mean initial crack and final fracture loads were measured and compared. The core framework curved in the occlusal direction had the highest final fracture loads; there were significant differences (P < 0.05) in the mean final fracture load, whereas initial fracture load, which fractured of veneered porcelain, did not show significant differences among three designs. The all-ceramic bridges on the implants made with Procera zirconium core frameworks had high final fracture load. The core framework design that curved in the occlusal direction helped the framework withstand the occlusal load, which results in reliable prostheses, especially in the molar region.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17559618     DOI: 10.1111/j.1365-2842.2007.01751.x

Source DB:  PubMed          Journal:  J Oral Rehabil        ISSN: 0305-182X            Impact factor:   3.837


  6 in total

1.  Comparison of implant versus tooth-supported zirconia-based single crowns in a split-mouth design: a 4-year clinical follow-up study.

Authors:  Mustafa Barış Güncü; Umut Cakan; Guliz Aktas; Güliz Nigar Güncü; Şenay Canay
Journal:  Clin Oral Investig       Date:  2016-02-29       Impact factor: 3.573

2.  Comparison of failure loads and compressive stress in Press on metal and Press on Y-TZP copings.

Authors:  Fahim Vohra; Mohammed Bin Shuwaish; Modhi Al Deeb; Rana Alhamdan; Naif Alotaibi; Tariq Abduljabbar
Journal:  Pak J Med Sci       Date:  2020 Nov-Dec       Impact factor: 1.088

3.  Randomized clinical trial of implant-supported ceramic-ceramic and metal-ceramic fixed dental prostheses: preliminary results.

Authors:  Josephine F Esquivel-Upshaw; Arthur E Clark; Jonathan J Shuster; Kenneth J Anusavice
Journal:  J Prosthodont       Date:  2013-06-12       Impact factor: 2.752

4.  Fracture Strength of Three-Unit Implant Supported Fixed Partial Dentures with Excessive Crown Height Fabricated from Different Materials.

Authors:  Vahideh Nazari; Safoura Ghodsi; Marzieh Alikhasi; Majid Sahebi; Ahmad Reza Shamshiri
Journal:  J Dent (Tehran)       Date:  2016-11

5.  Rationale for the use of CAD/CAM technology in implant prosthodontics.

Authors:  Jaafar Abduo; Karl Lyons
Journal:  Int J Dent       Date:  2013-04-16

6.  Effect of pontic framework design on the fracture resistance of implant-supported all-ceramic fixed partial dentures.

Authors:  Ozgur Inan; Asli Secilmis; Oguz Eraslan
Journal:  J Appl Oral Sci       Date:  2009 Sep-Oct       Impact factor: 2.698

  6 in total