Literature DB >> 17559183

Increased nuchal translucency thickness and normal karyotype: time for parental reassurance.

C M Bilardo1, M A Müller, E Pajkrt, S A Clur, M M van Zalen, E K Bijlsma.   

Abstract

OBJECTIVES: To study the outcome of pregnancy in chromosomally normal fetuses with increased nuchal translucency thickness (NT), with respect to fetal loss, structural defects and genetic syndromes with developmental delay, and to provide information that would be helpful for parental counseling on the residual risk of adverse outcome when ultrasound findings are normal.
METHODS: We reviewed the outcome of all pregnancies presenting at the Academic Medical Centre in Amsterdam with increased NT between January 1994 and March 2005. Fetal karyotyping and two-step ultrasound investigation at 13-18 and 20-24 weeks' gestation were offered in all cases. Particular attention was paid to the relationship between normal karyotype, ultrasound findings at the 20-24-week scan and subsequent pregnancy outcome. An adverse outcome was defined as miscarriage, intrauterine death, termination of pregnancy at parental request or the finding of one or more structural defects or genetic disorders.
RESULTS: A total of 675 fetuses with increased NT, known karyotype and known pregnancy outcome was analyzed. A chromosomal anomaly was detected in 224 (33%) fetuses. In 451 (67%) fetuses, the karyotype was normal. The overall incidence of an adverse pregnancy outcome in this group was 19% and, when analyzed according to the initial degree of increase in NT, the likelihood of an adverse outcome increased with increasing NT, ranging from 8% to 80%. 425 fetuses underwent a detailed second-trimester ultrasound scan. Anomalies were detected, at the time of ultrasound or after birth, in 54 (13%) of these fetuses (17 isolated cardiac defects, 14 other structural defects and 23 genetic disorders). An adverse pregnancy outcome was recorded in 4% of cases in which there were normal findings at the 20-week scan. Seven of these cases were classified as 'potentially amenable' to ultrasound detection. With exclusion of these cases, the chance of a healthy baby, if the 20-week scan was completely normal, was 98%. Genetic syndromes with dysmorphic features and neurodevelopmental delay occurred in seven (1.6%) of the fetuses with normal karyotype. In three of these pregnancies, non-specific suspicious ultrasound findings (nuchal edema, mild pyelectasis, pericardial effusion) were observed at the mid-trimester scan and in two others, subtle cardiac defects were detected after delivery. In the remaining two cases (0.5%) the mid-trimester scan was completely normal and no structural defects were observed after delivery.
CONCLUSION: After exclusion of chromosomal anomalies, one out of five fetuses with increased NT has an adverse pregnancy outcome. The chance of an uneventful pregnancy outcome depends on the initial degree of increase in NT. However, if the detailed ultrasound examination at around 20 weeks is normal, a favorable outcome can be expected with confidence, irrespective of initially increased NT.

Entities:  

Mesh:

Year:  2007        PMID: 17559183     DOI: 10.1002/uog.4044

Source DB:  PubMed          Journal:  Ultrasound Obstet Gynecol        ISSN: 0960-7692            Impact factor:   7.299


  18 in total

1.  Increased nuchal traslucency in normal karyotype fetuses.

Authors:  Roberta De Domenico; Marianna Faraci; Entela Hyseni; Fosca A F Di Prima; Oriana Valenti; Santo Monte; Elsa Giorgio; Eliana Renda
Journal:  J Prenat Med       Date:  2011-04

Review 2.  Adverse pregnancy outcomes after abnormal first-trimester screening for aneuploidy.

Authors:  Laura Goetzl
Journal:  Clin Lab Med       Date:  2010-09       Impact factor: 1.935

3.  Fetal exome sequencing for isolated increased nuchal translucency: should we be doing it?

Authors:  R Mellis; R Y Eberhardt; S J Hamilton; D J McMullan; M D Kilby; E R Maher; M E Hurles; J L Giordano; V Aggarwal; D B Goldstein; R J Wapner; L S Chitty
Journal:  BJOG       Date:  2021-09-14       Impact factor: 7.331

4.  Prenatal diagnosis of fetal aneuploidies using QF-PCR: the egyptian study.

Authors:  Shereen H Atef; Sawsan S Hafez; Nermein H Mahmoud; Sanaa M Helmy
Journal:  J Prenat Med       Date:  2011-10

5.  Clinical experience with multiplex ligation-dependent probe amplification for microdeletion syndromes in prenatal diagnosis: 7522 pregnant Korean women.

Authors:  Dongsook Lee; Sohyun Na; Surim Park; Sanghee Go; Jinyoung Ma; Soonha Yang; Kichul Kim; Seunggwan Lee; Doyeong Hwang
Journal:  Mol Cytogenet       Date:  2019-02-26       Impact factor: 2.009

6.  Analysis of quality of nuchal translucency measurements: its role in prenatal diagnosis.

Authors:  Carmen Comas Gabriel; M Echevarria; I Rodríguez; B Serra
Journal:  ScientificWorldJournal       Date:  2011-12-12

7.  Chromosomally and Anatomically Normal Fetuses With Increased First Trimester Nuchal Translucency Conceived by ICSI.

Authors:  Maryam Niknejadi; Hadieh Haghighi
Journal:  Iran J Radiol       Date:  2015-04-21       Impact factor: 0.212

8.  Increased nuchal translucency and pregnancy outcome.

Authors:  A Tahmasebpour; N Baradaran Rafiee; S Ghaffari; A Jamal
Journal:  Iran J Public Health       Date:  2012-11-01       Impact factor: 1.429

9.  Enlarged NT (≥3.5 mm) in the first trimester - not all chromosome aberrations can be detected by NIPT.

Authors:  Malgorzata I Srebniak; Merel C de Wit; Karin E M Diderich; Lutgarde C P Govaerts; Marieke Joosten; Maarten F C M Knapen; Marnix J Bos; Gerda A G Looye-Bruinsma; Mieke Koningen; Attie T J I Go; Robert Jan H Galjaard; Diane Van Opstal
Journal:  Mol Cytogenet       Date:  2016-09-07       Impact factor: 2.009

10.  Ultrasound and echocardiographic findings obtained in the second and third trimesters of gestation in fetuses with normal karyotype and increased nuchal translucency.

Authors:  Hanna Moczulska; Katarzyna Janiak; Maciej Słodki; Maria Respondek-Liberska
Journal:  J Ultrason       Date:  2013-03-30
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.