Is flow cytometry really adapted to the determination of sperm concentration?

J-C Lu1, F Chen, H-R Xu, Y-M Wu, X-Y Xia, Y-F Huang, N-Q Lu.   

Abstract

It has been reported that flow cytometry can be used as a reference procedure to determine sperm concentrations in quality control schemes in andrology laboratories, but there are no convincing quality control data. To understand comprehensively whether flow cytometry can be used to determine sperm concentration, sperm concentrations of 85 human semen samples were detected using three different methods, namely flow cytometry, computer-assisted semen analysis (CASA) and manual counting with a cell-VU chamber. The bead concentrations of both low [(18+/-2.5)x10(6)/mL] and high [(35+/-5)x10(6)/mL] pre-calibrated standard latex bead solutions were also determined with flow cytometry. The results showed that bead concentrations of both low and high pre-calibrated standard latex bead solutions counted five times with flow cytometry were (21.37+/-0.85)x10(6)/mL and (45.95+/-1.76)x10(6)/mL, respectively. Coefficient variances (CVs) and relative errors (REs) were 4%, 15.51% and 3.84%, 31.3% for low and high latex bead solutions, respectively. The overall correlation between values measured with flow cytometry and values measured with the cell-VU chamber and the CASA system was significant. However, flow cytometry overestimated the sperm concentration by 109% compared to the results with the cell-VU chamber. Moreover, for the azoospermic samples analysed, the sperm concentration was estimated at 0.12 (range from 0.04 to 0.24)x10(6)/mL. In conclusion, the data demonstrated that flow cytometry can result in an overestimation of both bead counting and sperm concentration, suggesting that flow cytometry is an inappropriate method for sperm counting, especially in the case of azoospermia.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17558894     DOI: 10.1080/00365510601124032

Source DB:  PubMed          Journal:  Scand J Clin Lab Invest        ISSN: 0036-5513            Impact factor:   1.713


  4 in total

1.  A survey on the status of semen analysis in 118 laboratories in China.

Authors:  Jin-Chun Lu; Hong-Ye Zhang; Yu-An Hu; Yu-Feng Huang; Nian-Qing Lü
Journal:  Asian J Androl       Date:  2009-02-23       Impact factor: 3.285

Review 2.  Flow cytometry for the assessment of animal sperm integrity and functionality: state of the art.

Authors:  Md Sharoare Hossain; Anders Johannisson; Margareta Wallgren; Szabolcs Nagy; Amanda Pimenta Siqueira; Heriberto Rodriguez-Martinez
Journal:  Asian J Androl       Date:  2011-04-11       Impact factor: 3.285

3.  Sources of variation in flow cytometric analysis of aquatic species sperm: The effect of cryoprotectants on flow cytometry scatter plots and subsequent population gating.

Authors:  Jonathan Daly; Terrence R Tiersch
Journal:  Aquaculture       Date:  2012-10-11       Impact factor: 4.242

4.  Determination of sperm concentration using flow cytometry with simultaneous analysis of sperm plasma membrane integrity in zebrafish Danio rerio.

Authors:  Huiping Yang; Jonathan Daly; Terrence R Tiersch
Journal:  Cytometry A       Date:  2015-11-18       Impact factor: 4.355

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.