Clinical outcome and echocardiographic predictors of aortic valve replacement in patients with bicuspid aortic valve.

Shaheeda Ahmed1, George N Honos, Anne D Walling, Caroline M Michel, Igal A Sebag, Lawrence G Rudski, Judith Therrien.   

Abstract

BACKGROUND: Clinical outcomes and echocardiographic parameters associated with aortic valve replacement (AVR) for bicuspid aortic valve are scarce.
METHODS: We conducted retrospective analysis of 208 adults with bicuspid aortic valve referred for transthoracic echocardiograms.
RESULTS: The Kaplan-Meier survival free of death or need for cardiac surgery was 72% at 5 years. Cardiac surgery was performed in 19%, the majority (68%) for symptomatic aortic stenosis. Peak gradient 80 mm Hg or greater (hazard ratio 11.8, 95% confidence interval 3.7-37.8, P < .0001) and aortic valve area less than or equal to 0.75 cm(2) (hazard ratio 2.9, 95% confidence interval 1.0-8.5, P = .05) predicted the need for AVR. Patients with a large (54%) versus normal left ventricular outflow tract dimension underwent AVR for symptomatic aortic stenosis at a larger calculated aortic valve area (1.07 +/- 0.21 vs 0.75 +/- 0.18 cm(2), P < .0001) but at a similar peak gradient and velocity ratio (76 +/- 19 vs 76 +/- 22 mm Hg, P = not significant; 0.23 +/- 0.06 vs 0.26 +/- 0.12, P = not significant, respectively).
CONCLUSIONS: Clinical events are common among patients with bicuspid aortic valve. Peak gradient 80 mm Hg or more and aortic valve area less than or equal to 0.75 cm(2) predicts the need for AVR. Gradients and velocity ratio better reflect the hemodynamic burden of aortic stenosis in patients with a large left ventricular outflow tract.

Entities:  

Mesh:

Year:  2007        PMID: 17555932     DOI: 10.1016/j.echo.2007.01.003

Source DB:  PubMed          Journal:  J Am Soc Echocardiogr        ISSN: 0894-7317            Impact factor:   5.251


  3 in total

Review 1.  A roadmap to investigate the genetic basis of bicuspid aortic valve and its complications: insights from the International BAVCon (Bicuspid Aortic Valve Consortium).

Authors:  Siddharth K Prakash; Yohan Bossé; Jochen D Muehlschlegel; Hector I Michelena; Giuseppe Limongelli; Alessandro Della Corte; Francesca R Pluchinotta; Maria Giovanna Russo; Artur Evangelista; D Woodrow Benson; Simon C Body; Dianna M Milewicz
Journal:  J Am Coll Cardiol       Date:  2014-08-26       Impact factor: 24.094

2.  Diagnostic accuracy study of routine echocardiography for bicuspid aortic valve: a retrospective study and meta-analysis.

Authors:  Mathias Hillebrand; Dietmar Koschyk; Pia Ter Hark; Helke Schüler; Meike Rybczynski; Jürgen Berger; Amit Gulati; Alexander M Bernhardt; Christian Detter; Evaldas Girdauskas; Stefan Blankenberg; Yskert von Kodolitsch
Journal:  Cardiovasc Diagn Ther       Date:  2017-08

3.  Prognostic value of echocardiography with particular reference to patients with valvular heart disease.

Authors:  Wyatt Unger; Maggie Diller; Nishant Kalra; Vincent L Sorrell
Journal:  F1000 Med Rep       Date:  2009-12-15
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.