Literature DB >> 17555930

The evaluation of real-time 3-dimensional transthoracic echocardiography for the preoperative functional assessment of patients with mitral valve prolapse: a comparison with 2-dimensional transesophageal echocardiography.

Rajan Sharma1, Jon Mann, Linda Drummond, Steve A Livesey, Iain A Simpson.   

Abstract

OBJECTIVE: We sought to compare the feasibility and accuracy of transthoracic real-time 3-dimensional echocardiography (RT-3DE) with transesophageal echocardiography (TEE) for the preoperative functional assessment of patients with mitral valve prolapse.
METHODS: In 44 patients with severe mitral regurgitation caused by type 2 valve dysfunction, TEE and RT-3DE were performed 24 hours before surgery and analyzed by two separate observers. TEE and RT-3DE images were acquired digitally and stored for offline analysis. The echocardiographic results were validated intraoperatively.
RESULTS: Five patients did not have image quality suitable for analysis with RT-3DE and were excluded from analysis, leaving a sample size of 39. In total, 54 of 334 analyzed mitral valve segments were diseased. Prolapse of a single mitral valve segment was present in 25 patients and 14 patients had complex disease involving two or more segments. Sensitivity, specificity, and accuracy for TEE in identification of diseased segments were 94%, 100%, and 96%, respectively. The same values for RT-3DE were 91%, 100%, and 94%, respectively. The differences were not statistically significant. Accuracies were not significantly different according to segment location. Interobserver agreement was 92% for TEE and 88% for RT-3DE (P = nonsignificant).
CONCLUSIONS: RT-3DE is feasible with comparative accuracy to TEE for precise anatomic localization of prolapsing mitral valve segments. However, the technique is limited by poor image quality in 11% of patients.

Entities:  

Mesh:

Year:  2007        PMID: 17555930     DOI: 10.1016/j.echo.2007.01.028

Source DB:  PubMed          Journal:  J Am Soc Echocardiogr        ISSN: 0894-7317            Impact factor:   5.251


  12 in total

Review 1.  Cardiac imaging in valvular heart disease.

Authors:  W S Choo; R P Steeds
Journal:  Br J Radiol       Date:  2011-12       Impact factor: 3.039

2.  Real-time three-dimensional transoesophageal echocardiography: a new intraoperative feasible and useful technology in cardiac surgery.

Authors:  Paola Gripari; Gloria Tamborini; Paolo Barbier; Anna C Maltagliati; Claudia A Galli; Manuela Muratori; Luca Salvi; Erminio Sisillo; Francesco Alamanni; Mauro Pepi
Journal:  Int J Cardiovasc Imaging       Date:  2010-03-30       Impact factor: 2.357

3.  Quantification of mitral valve apparatus by three-dimensional transesophageal echocardiography: in vitro validation study comparing two different analysis systems.

Authors:  Ken Saito; Hiroyuki Okura; Nozomi Watanabe; Koichiro Imai; Tomoko Tamada; Terumasa Koyama; Akihiro Hayashida; Yoji Neishi; Takahiro Kawamoto; Kiyoshi Yoshida
Journal:  J Echocardiogr       Date:  2011-05-21

Review 4.  Three-dimensional echocardiography of the mitral valve: lessons learned.

Authors:  Francesco Maffessanti; Oana Mirea; Gloria Tamborini; Mauro Pepi
Journal:  Curr Cardiol Rep       Date:  2013-07       Impact factor: 2.931

5.  Quantitative mitral valve modeling using real-time three-dimensional echocardiography: technique and repeatability.

Authors:  Arminder Singh Jassar; Clayton J Brinster; Mathieu Vergnat; J Daniel Robb; Thomas J Eperjesi; Alison M Pouch; Albert T Cheung; Stuart J Weiss; Michael A Acker; Joseph H Gorman; Robert C Gorman; Benjamin M Jackson
Journal:  Ann Thorac Surg       Date:  2011-01       Impact factor: 4.330

6.  Assessment of mitral valve disease: a review of imaging modalities.

Authors:  Shweta R Motiwala; Francesca N Delling
Journal:  Curr Treat Options Cardiovasc Med       Date:  2015-07

Review 7.  Three-dimensional echocardiography. New possibilities in mitral valve assessment.

Authors:  Jorge Solis; Marta Sitges; Robert A Levine; Judy Hung
Journal:  Rev Esp Cardiol       Date:  2009-02       Impact factor: 4.753

8.  Transthoracic echocardiography in patients undergoing mitral valve repair: comparison of new transthoracic 3D techniques to 2D transoesophageal echocardiography in the localization of mitral valve prolapse.

Authors:  Paola Gripari; Massimo Mapelli; Ilaria Bellacosa; Concetta Piazzese; Maria Milo; Laura Fusini; Manuela Muratori; Sarah Ghulam Ali; Gloria Tamborini; Mauro Pepi
Journal:  Int J Cardiovasc Imaging       Date:  2018-02-26       Impact factor: 2.357

9.  Congenital mitral valve lesions : Correlation between morphology and imaging.

Authors:  Bo Remenyi; Tom L Gentles
Journal:  Ann Pediatr Cardiol       Date:  2012-01

10.  Real-time three-dimensional transthoracic echocardiography in daily practice: initial experience.

Authors:  Ashraf M Anwar; Youssef F M Nosir; Siti Khairani Zainal-Abidin; Aref Ajam; Hassan Chamsi-Pasha
Journal:  Cardiovasc Ultrasound       Date:  2012-03-26       Impact factor: 2.062

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.