Development of an ultrasmall C-band linear accelerator guide for a four-dimensional image-guided radiotherapy system with a gimbaled x-ray head.

Yuichiro Kamino1, Sadao Miura, Masaki Kokubo, Ichiro Yamashita, Etsuro Hirai, Masahiro Hiraoka, Junzo Ishikawa.   

Abstract

We are developing a four-dimensional image-guided radiotherapy system with a gimbaled x-ray head. It is capable of pursuing irradiation and delivering irradiation precisely with the help of an agile moving x-ray head on the gimbals. Requirements for the accelerator guide were established, system design was developed, and detailed design was conducted. An accelerator guide was manufactured and basic beam performance and leakage radiation from the accelerator guide were evaluated at a low pulse repetition rate. The accelerator guide including the electron gun is 38 cm long and weighs about 10 kg. The length of the accelerating structure is 24.4 cm. The accelerating structure is a standing wave type and is composed of the axial-coupled injector section and the side-coupled acceleration cavity section. The injector section is composed of one prebuncher cavity, one buncher cavity, one side-coupled half cavity, and two axial coupling cavities. The acceleration cavity section is composed of eight side-coupled nose reentrant cavities and eight coupling cavities. The electron gun is a diode-type gun with a cerium hexaboride (CeB6) direct heating cathode. The accelerator guide can be operated without any magnetic focusing device. Output beam current was 75 mA with a transmission efficiency of 58%, and the average energy was 5.24 MeV. Beam energy was distributed from 4.95 to 5.6 MeV. The beam profile, measured 88 mm from the beam output hole on the axis of the accelerator guide, was 0.7 mm X 0.9 mm full width at half maximum (FWHM) width. The beam loading line was 5.925 (MeV)-Ib (mA) X 0.00808 (MeV/mA), where Ib is output beam current. The maximum radiation leakage of the accelerator guide at 100 cm from the axis of the accelerator guide was calculated as 0.33 cGy/min at the rated x-ray output of 500 cGy/min from the measured value. This leakage requires no radiation shielding for the accelerator guide itself per IEC 60601-2-1.

Entities:  

Mesh:

Year:  2007        PMID: 17555261     DOI: 10.1118/1.2723878

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  13 in total

1.  Performance of a clinical gridded electron gun in magnetic fields: Implications for MRI-linac therapy.

Authors:  Brendan Whelan; Lois Holloway; Dragos Constantin; Brad Oborn; Magdalena Bazalova-Carter; Rebecca Fahrig; Paul Keall
Journal:  Med Phys       Date:  2016-11       Impact factor: 4.071

2.  Evaluation of cone-beam computed tomography image quality assurance for Vero4DRT system.

Authors:  Hideharu Miura; Shuichi Ozawa; Masahiro Hayata; Shintarou Tsuda; Tsubasa Enosaki; Kiyoshi Yamada; Yasushi Nagata
Journal:  Rep Pract Oncol Radiother       Date:  2017-04-25

3.  Development of a dose verification system for Vero4DRT using Monte Carlo method.

Authors:  Yoshitomo Ishihara; Akira Sawada; Mitsuhiro Nakamura; Yuki Miyabe; Hiroaki Tanabe; Shuji Kaneko; Kenji Takayama; Takashi Mizowaki; Masaki Kokubo; Masahiro Hiraoka
Journal:  J Appl Clin Med Phys       Date:  2014-11-08       Impact factor: 2.102

4.  Effect of VERO pan-tilt motion on the dose distribution.

Authors:  Heru Prasetio; Indra Yohannes; Christoph Bert
Journal:  J Appl Clin Med Phys       Date:  2017-06-06       Impact factor: 2.102

5.  Commissioning and initial stereotactic ablative radiotherapy experience with Vero.

Authors:  Timothy D Solberg; Paul M Medin; Ezequiel Ramirez; Chuxiong Ding; Ryan D Foster; John Yordy
Journal:  J Appl Clin Med Phys       Date:  2014-03-06       Impact factor: 2.102

6.  Long-term stability assessment of a 4D tumor tracking system integrated into a gimbaled linear accelerator.

Authors:  Mami Akimoto; Mitsuhiro Nakamura; Yuki Miyabe; Nobutaka Mukumoto; Kenji Yokota; Takashi Mizowaki; Masahiro Hiraoka
Journal:  J Appl Clin Med Phys       Date:  2015-09-08       Impact factor: 2.102

7.  Baseline correction of a correlation model for improving the prediction accuracy of infrared marker-based dynamic tumor tracking.

Authors:  Mami Akimoto; Mitsuhiro Nakamura; Nobutaka Mukumoto; Masahiro Yamada; Hiroaki Tanabe; Nami Ueki; Shuji Kaneko; Yukinori Matsuo; Takashi Mizowaki; Masaki Kokubo; Masahiro Hiraoka
Journal:  J Appl Clin Med Phys       Date:  2015-03-08       Impact factor: 2.102

8.  Accuracy of image guidance using free-breathing cone-beam computed tomography for stereotactic lung radiotherapy.

Authors:  Takeshi Kamomae; Hajime Monzen; Shinichi Nakayama; Rika Mizote; Yuuichi Oonishi; Soichiro Kaneshige; Takashi Sakamoto
Journal:  PLoS One       Date:  2015-05-08       Impact factor: 3.240

9.  Dosimetric impact of gold markers implanted closely to lung tumors: a Monte Carlo simulation.

Authors:  Takehiro Shiinoki; Akira Sawada; Yoshitomo Ishihara; Yuki Miyabe; Yukinori Matsuo; Takashi Mizowaki; Masaki Kokubo; Masahiro Hiraoka
Journal:  J Appl Clin Med Phys       Date:  2014-05-08       Impact factor: 2.102

10.  Effect of audio instruction on tracking errors using a four-dimensional image-guided radiotherapy system.

Authors:  Mitsuhiro Nakamura; Akira Sawada; Nobutaka Mukumoto; Kunio Takahashi; Takashi Mizowaki; Masaki Kokubo; Masahiro Hiraoka
Journal:  J Appl Clin Med Phys       Date:  2013-09-06       Impact factor: 2.102

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.