Energy dependence of commercially available diode detectors for in-vivo dosimetry.

Amarjit S Saini1, Timothy C Zhu.   

Abstract

The energy dependence of commercially available diode detectors was measured for nominal accelerating potential ranging between Co-60 and 17 MV. The measurements were performed in a liquid water phantom at 5 cm depth for 10 x 10 cm2 collimator setting and source-to-detector distance of 100 cm. The response (nC/Gy) was normalized to Co-60 beam after corrections for the dose rate and temperature dependences for each diode. The energy dependence, calculated by taking the percent difference between the maximum and minimum sensitivity normalized to Co-60 beam, varied by 39% for the n-type Isorad Red, 26% for the n-type Isorad Electron, 19% for the QED Red (p-type), 15% for the QED Electron (p-type), 11% for the QED Blue (p-type), and 6% for the EDP10 diode for nominal accelerating potential between Co-60 and 17 MV. It varied by 34% for the Isorad-3 Gold #1 and #2, 35% for the Veridose Green, 15% for the Veridose Yellow, 9% for the Veridose Electron, 21% for the n-type QED Gold, 24% for the n-type QED Red, 3% for the EDP23G, 2% for the PFD (photon field detector), 7% for the EDP103G, and 16% for the EDP203G for nominal accelerating potential between Co-60 and 15 MV. The magnitude of the energy dependence is verified by Monte Carlo simulation. We concluded that the energy dependence does not depend on whether the diode is n- or p-type but rather depends mainly on the material around the die such as the buildup and the geometry of the buildup material. As a result, the value of the energy dependence can vary for each individual diode depending on the actual geometry and should be used with caution.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17555252     DOI: 10.1118/1.2719365

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  14 in total

1.  Radioluminescence characterization of in situ x-ray nanodosimeters: Potential real-time monitors and modulators of external beam radiation therapy.

Authors:  Jeffrey S Souris; Shih-Hsun Cheng; Charles Pelizzari; Nai-Tzu Chen; Patrick La Riviere; Chin-Tu Chen; Leu-Wei Lo
Journal:  Appl Phys Lett       Date:  2014-11-20       Impact factor: 3.791

2.  Monte Carlo-based energy response studies of diode dosimeters in radiotherapy photon beams.

Authors:  C Arun; T Palani Selvam; Verma Dinkar; Prabhat Munshi; Manjit Singh Kalra
Journal:  Radiol Phys Technol       Date:  2012-11-20

3.  Cherenkov imaging for total skin electron therapy (TSET).

Authors:  Yunhe Xie; Heather Petroccia; Amit Maity; Tianshun Miao; Yihua Zhu; Petr Bruza; Brian W Pogue; John P Plastaras; Lei Dong; Timothy C Zhu
Journal:  Med Phys       Date:  2019-11-26       Impact factor: 4.071

4.  Dosimetric verification by using the ArcCHECK system and 3DVH software for various target sizes.

Authors:  Jin Ho Song; Hun-Joo Shin; Chul Seung Kay; Seok Hyun Son
Journal:  PLoS One       Date:  2015-03-25       Impact factor: 3.240

5.  Sensitive Fibre-Based Thermoluminescence Detectors for High Resolution In-Vivo Dosimetry.

Authors:  Mostafa Ghomeishi; G Amouzad Mahdiraji; F R Mahamd Adikan; N M Ung; D A Bradley
Journal:  Sci Rep       Date:  2015-08-28       Impact factor: 4.379

6.  Commissioning compensator-based IMRT on the Pinnacle treatment planning system.

Authors:  Daniel Opp; Kenneth Forster; Vladimir Feygelman
Journal:  J Appl Clin Med Phys       Date:  2011-03-08       Impact factor: 2.102

7.  Evaluation of a new VMAT QA device, or the "X" and "O" array geometries.

Authors:  Vladimir Feygelman; Geoffrey Zhang; Craig Stevens; Benjamin E Nelms
Journal:  J Appl Clin Med Phys       Date:  2011-01-31       Impact factor: 2.102

8.  A Monte Carlo and experimental investigation of the dosimetric behavior of low- and medium-perturbation diodes used for entrance in vivo dosimetry in megavoltage photon beams.

Authors:  Mohammad Amin Mosleh-Shirazi; Sareh Karbasi; Daryoush Shahbazi-Gahrouei; Shahram Monadi
Journal:  J Appl Clin Med Phys       Date:  2012-11-08       Impact factor: 2.102

9.  Validation of an improved helical diode array and dose reconstruction software using TG-244 datasets and stringent dose comparison criteria.

Authors:  Saeed Ahmed; Benjamin Nelms; Jakub Kozelka; Geoffrey Zhang; Eduardo Moros; Vladimir Feygelman
Journal:  J Appl Clin Med Phys       Date:  2016-11-08       Impact factor: 2.102

10.  Establishment of linear accelerator-based image guided radiotherapy for orthotopic 4T1 mouse mammary tumor model.

Authors:  Seung-Heon Lee; Ji-Young Kim; Kyu-Chan Lee; Jeong-Seok Nam; Jinho Choi; Seok-Ho Lee; Ki-Hoon Sung; So-Hyun Ahn
Journal:  Lab Anim Res       Date:  2014-06-23
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.