Literature DB >> 17553643

Analysis of ketamine and norketamine in urine by automatic solid-phase extraction (SPE) and positive ion chemical ionization-gas chromatography-mass spectrometry (PCI-GC-MS).

Eun-mi Kim1, Ju-seon Lee, Sang-kil Choi, Mi-ae Lim, Hee-sun Chung.   

Abstract

Ketamine (KT) is widely abused for hallucination and also misused as a "date-rape" drug in recent years. An analytical method using positive ion chemical ionization-gas chromatography-mass spectrometry (PCI-GC-MS) with an automatic solid-phase extraction (SPE) apparatus was studied for the determination of KT and its major metabolite, norketamine (NK), in urine. Six ketamine suspected urine samples were provided by the police. For the research of KT metabolism, KT was administered to SD rats by i.p. at a single dose of 5, 10 and 20mg/kg, respectively, and urine samples were collected 24, 48 and 72 h after administration. For the detection of KT and NK, urine samples were extracted on an automatic SPE apparatus (RapidTrace, Zymark) with mixed mode type cartridge, Drug-Clean (200 mg, Alltech). The identification of KT and NK was by PCI-GC-MS. m/z238 (M+1), 220 for KT, m/z 224 (M+1), 207 for NK and m/z307 (M+1) for Cocaine-D(3) as internal standard were extracted from the full-scan mass spectrum and the underlined ions were used for quantitation. Extracted calibration curves were linear from 50 to 1000 ng/mL for KT and NK with correlation coefficients exceeding 0.99. The limit of detection (LOD) was 25 ng/mL for KT and NK. The limit of quantitation (LOQ) was 50 ng/mL for KT and NK. The recoveries of KT and NK at three different concentrations (86, 430 and 860 ng/mL) were 53.1 to 79.7% and 45.7 to 83.0%, respectively. The intra- and inter-day run precisions (CV) for KT and NK were less than 15.0%, and the accuracies (bias) for KT and NK were also less than 15% at the three different concentration levels (86, 430 and 860 ng/mL). The analytical method was also applied to real six KT suspected urine specimens and KT administered rat urines, and the concentrations of KT and NK were determined. Dehydronorketamine (DHNK) was also confirmed in these urine samples, however the concentration of DHNK was not calculated. SPE is simple, and needs less organic solvent than liquid-liquid extraction (LLE), and PCI-GC-MS can offer both qualitative and quantitative information for urinalysis of KT in forensic analysis.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17553643     DOI: 10.1016/j.forsciint.2007.04.217

Source DB:  PubMed          Journal:  Forensic Sci Int        ISSN: 0379-0738            Impact factor:   2.395


  4 in total

1.  Rapid detection and quantitation of drugs-of-abuse by wooden-tip electrospray ionization mass spectrometry.

Authors:  Tsz-Tsun Ng; Pui-Kin So; Bin Hu; Zhong-Ping Yao
Journal:  J Food Drug Anal       Date:  2018-10-01       Impact factor: 6.157

2.  A label-free immunosensor for ultrasensitive detection of ketamine based on quartz crystal microbalance.

Authors:  Ya Yang; Yifeng Tu; Xiaoshu Wang; Jinyin Pan; Yun Ding
Journal:  Sensors (Basel)       Date:  2015-04-13       Impact factor: 3.576

3.  Intravesical Instillation of Norketamine, a Ketamine Metabolite, and Induced Bladder Functional Changes in Rats.

Authors:  Chung-Hsin Yeh; Bo-He Chen; Xiao-Wen Tseng; Chun-Hou Liao; Wei-Kung Tsai; Han-Sun Chiang; Yi-No Wu
Journal:  Toxics       Date:  2021-06-30

4.  A critical point in chiral chromatography-mass spectrometry analysis of ketamine metabolites.

Authors:  Andrea Barbarossa; Anisa Bardhi; Teresa Gazzotti; Giampiero Pagliuca
Journal:  Drug Test Anal       Date:  2021-06-15       Impact factor: 3.345

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.