Literature DB >> 17552495

Suspension array with shape-coded silica nanotubes for multiplexed immunoassays.

Bo He1, Sang Jun Son, Sang Bok Lee.   

Abstract

A suspension array for multiplexed immunoassays has been developed using shape-coded silica nanotubes (SNTs) as coding materials. Fabricated by multistep anodization template synthesis, each shape-coded SNT has several segments with different reflectance values depending on their diameters and wall thicknesses. Therefore, the code of each SNT can be "read-out" under a conventional optical microscope. The suspension array with shape-coded SNTs has shown high stability and dispersibility in aqueous buffer media and high detection sensitivity. The SNTs have not shown any visible degradation while submerged in aqueous solution for 7 months, the tubular structure and silanol groups on the inner and outer surfaces allow SNTs to disperse evenly in buffer solution, and the detection limit of an IgG protein is about 6 pM with 1.5 x 10(6) SNTs per mL. We have demonstrated the high selectivity of the SNTs suspension array for the detection of multianalytes in the multiplexed immunoassay experiments.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17552495     DOI: 10.1021/ac0704964

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  10 in total

1.  Non-positional cell microarray prepared by shape-coded polymeric microboards: A new microarray format for multiplex and high throughput cell-based assays.

Authors:  Seung Hee Nam; Hyun Jong Lee; Kyung Jin Son; Won-Gun Koh
Journal:  Biomicrofluidics       Date:  2011-09-20       Impact factor: 2.800

Review 2.  Nanowire sensors for multiplexed detection of biomolecules.

Authors:  Bo He; Thomas J Morrow; Christine D Keating
Journal:  Curr Opin Chem Biol       Date:  2008-10       Impact factor: 8.822

3.  Shape-coded silica nanotubes for multiplexed bioassay: rapid and reliable magnetic decoding protocols.

Authors:  Bo He; Sung Kyoung Kim; Sang Jun Son; Sang Bok Lee
Journal:  Nanomedicine (Lond)       Date:  2010-01       Impact factor: 5.307

4.  Optimizing Multiplexed Detections of Diabetes Antibodies via Quantitative Microfluidic Droplet Array.

Authors:  Kai Duan; Gargi Ghosh; Joe Fujiou Lo
Journal:  Small       Date:  2017-10-09       Impact factor: 13.281

5.  Tunable Fabry-Pérot interferometer based on nanoporous anodic alumina for optical biosensing purposes.

Authors:  Abel Santos; Victor S Balderrama; María Alba; Pilar Formentín; Josep Ferré-Borrull; Josep Pallarès; Lluís F Marsal
Journal:  Nanoscale Res Lett       Date:  2012-07-03       Impact factor: 4.703

6.  Simultaneous Detection of Fenitrothion and Chlorpyrifos-Methyl with a Photonic Suspension Array.

Authors:  Xuan Wang; Zhongde Mu; Fengqi Shangguan; Ran Liu; Yuepu Pu; Lihong Yin
Journal:  PLoS One       Date:  2013-06-21       Impact factor: 3.240

7.  In-flow real-time detection of spectrally encoded microgels for miRNA absolute quantification.

Authors:  David Dannhauser; Filippo Causa; Edmondo Battista; Angela M Cusano; Domenico Rossi; Paolo A Netti
Journal:  Biomicrofluidics       Date:  2016-12-06       Impact factor: 2.800

Review 8.  Nanostructural Engineering of Nanoporous Anodic Alumina for Biosensing Applications.

Authors:  Josep Ferré-Borrull; Josep Pallarès; Gerard Macías; Lluis F Marsal
Journal:  Materials (Basel)       Date:  2014-07-18       Impact factor: 3.623

Review 9.  Nanoporous Anodic Alumina: A Versatile Platform for Optical Biosensors.

Authors:  Abel Santos; Tushar Kumeria; Dusan Losic
Journal:  Materials (Basel)       Date:  2014-05-30       Impact factor: 3.623

Review 10.  Nanoporous anodic alumina platforms: engineered surface chemistry and structure for optical sensing applications.

Authors:  Tushar Kumeria; Abel Santos; Dusan Losic
Journal:  Sensors (Basel)       Date:  2014-07-07       Impact factor: 3.576

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.