Literature DB >> 17551990

Analyses of pesticide residues in fruit-based baby food by liquid chromatography/electrospray ionization time-of-flight mass spectrometry.

Bienvenida Gilbert-López1, Juan F García-Reyes, Pilar Ortega-Barrales, Antonio Molina-Díaz, Amadeo R Fernández-Alba.   

Abstract

A liquid chromatography/electrospray ionization time-of-flight mass spectrometry (LC/ESI-TOFMS) method has been developed for the determination of 12 pesticides (namely, carbendazim, thiabendazole, imazalil, tridemorph, triadimefon, bitertanol, prochloraz, flutriafol, myclobutanil, iprodione, diphenylamine and procymidone) in fruit-based baby food (multi-fruit jars and juices intended for infant consumption). The developed method consists of a sample treatment step based on liquid-liquid extraction using acetonitrile, followed by a clean-up step based on dispersive solid-phase extraction (SPE) with a primary-secondary amine (PSA). Multi-fruit and apple juices were processed by a SPE procedure using Oasis HLB cartridges. Subsequent identification and quantitation was accomplished by LC/ESI-TOFMS analysis: the confirmation of the target pesticides was based on accurate mass measurements of selected ions (protonated molecules ([M+H]+) and fragment ions). Confirmation studies were accomplished at low concentration levels (10 microg kg-1) and accuracy errors lower than 2 ppm were obtained in most cases. Baby food extracts spiked at 10 microg kg-1 fortification level yielded average recoveries in the range 78-105% with relative standard deviations less than 10% for most of the analytes. Limits of detection (LODs) were between 0.1 and 4 microg kg-1 depending on the pesticide studied. Finally, the proposed method was applied to a total of 33 baby food samples from Spain and the United Kingdom. Although imazalil, thiabendazole and carbendazim were detected in a high number--over 60%- of baby food samples, none of the samples tested were found to be above the 0.01 mg kg-1 EU standard. Copyright (c) 2007 John Wiley & Sons, Ltd.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17551990     DOI: 10.1002/rcm.3062

Source DB:  PubMed          Journal:  Rapid Commun Mass Spectrom        ISSN: 0951-4198            Impact factor:   2.419


  1 in total

1.  A gold/Fe3O4 nanocomposite for use in a surface plasmon resonance immunosensor for carbendazim.

Authors:  Qian Li; Xiaowen Dou; Xiangsheng Zhao; Lei Zhang; Jiaoyang Luo; Xiaoyan Xing; Meihua Yang
Journal:  Mikrochim Acta       Date:  2019-04-30       Impact factor: 5.833

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.