Literature DB >> 17550602

A bleeding kiss: intramural haematoma secondary to balloon angioplasty.

Cheerag Shirodaria1, William J Van Gaal, Adrian P Banning.   

Abstract

BACKGROUND: Intramural coronary haematoma following percutaneous coronary intervention in the absence of coronary dissection is a rare phenomenon. CASE
PRESENTATION: A 69 year old lady with previous prosthetic aortic valve replacement underwent percutaneous coronary intervention (PCI) from the left mainstem to the left anterior descending artery (LAD) and kissing balloon inflations to the LAD and circumflex (Cx) arteries. Although intravascular ultrasound examination (IVUS) of both the LAD and Cx showed both vessels to be widely patent at the end of the procedure, she developed ischaemic chest pain six hours later. Repeat coronary angiography revealed a significant stenosis in the proximal Cx vessel, which was confirmed on IVUS to be intramural haematoma.
CONCLUSION: In patients taking warfarin in addition to standard antiplatelet therapy, kissing balloon inflations should be carried out with caution.

Entities:  

Mesh:

Year:  2007        PMID: 17550602      PMCID: PMC1891271          DOI: 10.1186/1476-7120-5-21

Source DB:  PubMed          Journal:  Cardiovasc Ultrasound        ISSN: 1476-7120            Impact factor:   2.062


Background

Intramural haematoma in a coronary artery is a rare complication of percutaneous coronary intervention. Haemorrhage commonly occurs due to subintimal dissection without a flap or reentry.[1,2] However, haematoma in the absence of coronary dissection with an intact media is rare.

Case presentation

A 69 year old lady with previous prosthetic aortic valve replacement and coronary bypass surgery (left internal mammary artery (LIMA) to the left anterior descending (LAD) artery) was admitted with exertional angina. Stress echocardiography had demonstrated ischemia in the LAD territory. Coronary angiography and intravascular ultrasound (IVUS) examination revealed a critical ostial stenosis in the native LAD (figure 1, panels A&B), with only a small amount of retrograde flow from the LIMA into the native LAD. IVUS examination of the circumflex (Cx) artery revealed no significant disease. A 16 mm Liberte (Boston Scientific) stent was deployed from the left mainstem (LMS) into the LAD, crossing the Cx ostium. Kissing balloon inflations were performed to the LAD and Cx, and an excellent angiographic result was achieved (figure 1, panel C). In particular, IVUS examination of the Cx at completion of the procedure showed that the vessel was widely patent, with no evidence of dissection (figure 1, panel D). Six hours after the procedure, the patient developed chest pain associated with new onset rapid atrial fibrillation (rate = 160 bpm) and ST segment depression in the lateral chest leads. Repeat coronary angiography revealed a significant stenosis in the proximal Cx vessel, which was confirmed on IVUS to be intramural haematoma (figure 1, panels E&F, see additional file 1). There was no evidence of coronary dissection, with the intima remaining intact. The LAD stent was widely patent with no evidence of haematoma. The new Cx lesion was successfully treated in a T-fashion with a 12 mm Liberte stent (Boston Scientific). Results were confirmed with IVUS.
Figure 1

Intramural haematoma secondary to balloon angioplasty. Panels A&B: Initial angiography and IVUS examination confirmed ostial LAD disease. Panel C: Post procedure angiography showed a good angiographic result in the LAD. Panel D: IVUS examination of the Cx revealed no evidence of dissection. Panels E&F: Repeat angiography revealed a significant stenosis in the proximal Cx, which was confirmed on IVUS to be intramural haematoma.

Intramural haematoma secondary to balloon angioplasty. Panels A&B: Initial angiography and IVUS examination confirmed ostial LAD disease. Panel C: Post procedure angiography showed a good angiographic result in the LAD. Panel D: IVUS examination of the Cx revealed no evidence of dissection. Panels E&F: Repeat angiography revealed a significant stenosis in the proximal Cx, which was confirmed on IVUS to be intramural haematoma.

Discussion

Although minor haemorrhage following dissection is common, haemorrhage with an intact media is rare. Although in this case coronary dissection remains a possible cause, a number of factors suggest that this was medial/adventitial haemorrhage. First, IVUS examination of both the LAD and Cx arteries at the end of the first intervention was normal. Second, it is unusual for a dissection to localise to such a short area of coronary artery. Third, the time course of events, with symptoms only becoming apparent many hours after the procedure had finished, would be unusual for procedural coronary dissection. Indeed, the only aggravating factor in this case was that the patient was taking warfarin in addition to aspirin and clopidogrel. At the time of the initial procedure, the patient's International Normalised Ratio (INR) was 3.3. A possible mechanism in our patient was haemorrhage occurring within the aortic wall due to rupture of the vasa vasorum.

Conclusion

In patients taking warfarin in addition to standard antiplatelet therapy, kissing balloon inflations should be carried out with caution.

Competing interests

The author(s) declare that they have no competing interests. All authors read and approved the final manuscript

Additional file 1

IVUS. The image file shows the IVUS run of the circumflex artery detailing the intramural haematoma. Click here for file
  2 in total

1.  Milking dissection: an unusual complication of emergency coronary artery stenting for acute occlusion.

Authors:  J C Stauffer; U Sigwart; J J Goy; L Kappenberger
Journal:  Am Heart J       Date:  1991-05       Impact factor: 4.749

2.  Extensive intramural hematoma as the cause of failed coronary angioplasty: diagnosis by intravascular ultrasound and treatment by stent implantation.

Authors:  G S Werner; H R Figulla; W Grosse; H Kreuzer
Journal:  Cathet Cardiovasc Diagn       Date:  1995-10
  2 in total
  3 in total

1.  Retrograde dissection during percutaneous coronary intervention: sealing of the entry site by covered stent implantation.

Authors:  Gian Battista Danzi; Alfonso Campanile; Fabiola B Sozzi; Carla Bonanomi
Journal:  BMJ Case Rep       Date:  2012-09-17

2.  Numerical simulation of arterial dissection during balloon angioplasty of atherosclerotic coronary arteries.

Authors:  Pierre Badel; Stéphane Avril; Michael A Sutton; Susan M Lessner
Journal:  J Biomech       Date:  2014-01-14       Impact factor: 2.712

3.  Intravascular ultrasound-guided troubleshooting in a large hematoma treated with fenestration using a cutting balloon.

Authors:  Hye Jin Noh; Jin-Ho Choi; Young Bin Song; Hyun Chul Jo; Ji Hyun Yang; Sang Min Kim; Hyun Jong Lee; Joon Hyuk Choi; Soo Hee Choi; Joo Yong Hahn; Seung Hyuk Choi; Hyeon Cheol Gwon
Journal:  Korean Circ J       Date:  2009-04-28       Impact factor: 3.243