Literature DB >> 17548125

Digital Butterworth filter for subtracting noise from low magnitude surface electromyogram.

Roger G T Mello1, Liliam F Oliveira, Jurandir Nadal.   

Abstract

This work presents a digital filter designed to delimitate the frequency band of surface electromyograms (EMG) and remove the mains noise and its harmonics, focusing the signal analysis during reduced muscle activity. A Butterworth filter was designed as the frequency-domain product of a second order, high-pass filter with cutoff frequency 10 Hz, an eighth order low-pass filter, with cutoff at 400 Hz and six stop-band filters, second order, centered at the 60 Hz mains noise and its harmonics until 360 Hz. The resulting filter was applied in both direct and reverse directions of the signals to avoid phase distortions. The performance was evaluated with a simulated EMG signal with additive noise in multiples of 60 Hz. A qualitative assessment was made with real EMG data, acquired from 16 subjects, with age from 20 to 32 years. Subjects were positioned in orthostatic position during 21s, being only the last second analyzed to assure stationarity. EMG were collected by Ag/AgCl electrodes on right lateral gastrocnemius, amplified with gain 5000, filtered in the band from 10 Hz to 1 kHz, and thus digitized with 2ksamples/s. The filter effectively removed the mains noise components, with attenuations greater than 96.6%. The attenuation of the simulated signal at frequencies below 15 Hz and at 60 Hz caused only a small reduction of total power, preserving the original spectrum. Thus, the filter resulted suitable to the proposed application.

Mesh:

Year:  2007        PMID: 17548125     DOI: 10.1016/j.cmpb.2007.04.004

Source DB:  PubMed          Journal:  Comput Methods Programs Biomed        ISSN: 0169-2607            Impact factor:   5.428


  9 in total

1.  Increased fall risk is associated with elevated co-contraction about the ankle during static balance challenges in older adults.

Authors:  Erika Nelson-Wong; Ryan Appell; Mike McKay; Hannah Nawaz; Joanna Roth; Robert Sigler; Jacqueline Third; Mark Walker
Journal:  Eur J Appl Physiol       Date:  2011-08-03       Impact factor: 3.078

2.  Filtering of surface EMG using ensemble empirical mode decomposition.

Authors:  Xu Zhang; Ping Zhou
Journal:  Med Eng Phys       Date:  2012-12-11       Impact factor: 2.242

3.  Denoising of HD-sEMG signals using canonical correlation analysis.

Authors:  M Al Harrach; S Boudaoud; M Hassan; F S Ayachi; D Gamet; J F Grosset; F Marin
Journal:  Med Biol Eng Comput       Date:  2016-05-25       Impact factor: 2.602

4.  Crossover assessment of cardiolocomotor synchronization during running.

Authors:  Lucenildo Silva Cerqueira; Aluizio D'Affonsêca Netto; Roger Gomes Tavares Mello; Jurandir Nadal
Journal:  Eur J Appl Physiol       Date:  2017-01-10       Impact factor: 3.078

5.  The effects of notch filtering on electrically evoked myoelectric signals and associated motor unit index estimates.

Authors:  Xiaoyan Li; William Z Rymer; Guanglin Li; Ping Zhou
Journal:  J Neuroeng Rehabil       Date:  2011-11-23       Impact factor: 4.262

6.  Repeatability of Clinical, Biomechanical, and Motor Control Profiles in People with and without Standing-Induced Low Back Pain.

Authors:  Erika Nelson-Wong; Jack P Callaghan
Journal:  Rehabil Res Pract       Date:  2010-07-18

7.  Model for prompt and effective classification of motion recovery after stroke considering muscle strength and coordination factors.

Authors:  Álvaro Costa-García; Ken-Ichi Ozaki; Hiroshi Yamasaki; Matti Itkonen; Fady Alnajjar S; Shotaro Okajima; Masanori Tanimoto; Izumi Kondo; Shingo Shimoda
Journal:  J Neuroeng Rehabil       Date:  2019-11-04       Impact factor: 4.262

8.  Exhausting repetitive piano tasks lead to local forearm manifestation of muscle fatigue and negatively affect musical parameters.

Authors:  Etienne Goubault; Felipe Verdugo; Justine Pelletier; Caroline Traube; Mickaël Begon; Fabien Dal Maso
Journal:  Sci Rep       Date:  2021-04-14       Impact factor: 4.379

9.  Designing a Low-noise, High-resolution, and Portable Four Channel Acquisition System for Recording Surface Electromyographic Signal.

Authors:  Akbar Pashaei; Mohammad Reza Yazdchi; Hamid Reza Marateb
Journal:  J Med Signals Sens       Date:  2015 Oct-Dec
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.