Literature DB >> 1754695

[Subcutaneous emphysema of the oral floor during cleaning of a bridge fixed on an IMZ implant. Case report].

E Van de Velde1, P Thielens, H Schautteet, R Vanclooster.   

Abstract

A case of subcutaneous emphysema following intraoral elimination of plaque and tooth shading, on a bridge fixed on implants, is presented. An instrument that produces a cleaning spray with a water-air-powder mixture was used. A few minutes after this cleaning procedure there was facial swelling. The patient experienced difficulties in breathing and in swallowing; symptoms of unilateral hearing loss were also noticed. The emphysema lasted for three days. Etiology, diagnosis, differential diagnosis, complications and management are discussed.

Entities:  

Mesh:

Year:  1991        PMID: 1754695

Source DB:  PubMed          Journal:  Rev Belge Med Dent (1984)        ISSN: 0775-0293


  10 in total

1.  Influence of different treatment approaches on the removal of early plaque biofilms and the viability of SAOS2 osteoblasts grown on titanium implants.

Authors:  Frank Schwarz; Anton Sculean; Georg Romanos; Monika Herten; Nadine Horn; Werner Scherbaum; Jürgen Becker
Journal:  Clin Oral Investig       Date:  2005-04-20       Impact factor: 3.573

2.  Nonsurgical treatment of moderate and advanced periimplantitis lesions: a controlled clinical study.

Authors:  Frank Schwarz; Katrin Bieling; Martin Bonsmann; Thilo Latz; Jürgen Becker
Journal:  Clin Oral Investig       Date:  2006-09-13       Impact factor: 3.573

Review 3.  Laser wavelengths and oral implantology.

Authors:  George E Romanos; Norbert Gutknecht; Sandra Dieter; Frank Schwarz; Roberto Crespi; Anton Sculean
Journal:  Lasers Med Sci       Date:  2009-05-09       Impact factor: 3.161

4.  Nonsurgical treatment of peri-implantitis using an air-abrasive device or mechanical debridement and local application of chlorhexidine. Twelve-month follow-up of a prospective, randomized, controlled clinical study.

Authors:  Gordon John; Narja Sahm; Jürgen Becker; Frank Schwarz
Journal:  Clin Oral Investig       Date:  2015-01-22       Impact factor: 3.573

5.  Comparative evaluation of roughness of titanium surfaces treated by different hygiene instruments.

Authors:  Otgonbayar Unursaikhan; Jung-Seok Lee; Jae-Kook Cha; Jung-Chul Park; Ui-Won Jung; Chang-Sung Kim; Kyoo-Sung Cho; Seong-Ho Choi
Journal:  J Periodontal Implant Sci       Date:  2012-06-30       Impact factor: 2.614

6.  The effect of Er:YAG laser irradiation on the surface microstructure and roughness of hydroxyapatite-coated implant.

Authors:  Seong-Won Kim; Young-Hyuk Kwon; Jong-Hyuk Chung; Seung-Il Shin; Yeek Herr
Journal:  J Periodontal Implant Sci       Date:  2010-12-31       Impact factor: 2.614

7.  Effect of erbium-doped: yttrium, aluminium and garnet laser irradiation on the surface microstructure and roughness of sand-blasted, large grit, acid-etched implants.

Authors:  Ji-Hun Lee; Young-Hyuk Kwon; Yeek Herr; Seung-Il Shin; Jong-Hyuk Chung
Journal:  J Periodontal Implant Sci       Date:  2011-06-30       Impact factor: 2.614

8.  Evaluation of the safety and efficiency of novel metallic implant scaler tips manufactured by the powder injection molding technique.

Authors:  Kyung A Chun; Kee-Yeon Kum; Woo-Cheol Lee; Seung-Ho Baek; Hae-Won Choi; Won-Jun Shon
Journal:  BMC Oral Health       Date:  2017-07-11       Impact factor: 2.757

9.  Management of Retrograde Peri-Implantitis Using an Air-Abrasive Device, Er,Cr:YSGG Laser, and Guided Bone Regeneration.

Authors:  Nikolaos Soldatos; Georgios E Romanos; Michelle Michaiel; Ali Sajadi; Nikola Angelov; Robin Weltman
Journal:  Case Rep Dent       Date:  2018-04-15

10.  Subcutaneous Facial Emphysema Following Open-Flap Air-Powder Abrasive Debridement for Peri-Implantitis: A Case Report and an Overview.

Authors:  Gerardo La Monaca; Nicola Pranno; Susanna Annibali; Iole Vozza; Maria Paola Cristalli
Journal:  Int J Environ Res Public Health       Date:  2021-12-16       Impact factor: 3.390

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.