| Literature DB >> 17546448 |
Irina B Karadjova1, Leonardo Lampugnani, Alessandro D'Ulivo, Massimo Onor, Dimiter L Tsalev.
Abstract
A rapid, accurate, and precise method is described for the determination of Pb in wine using continuous-flow hydride generation atomic fluorescence spectrometry (CF-HGAFS). Sample pretreatment consists of ten-fold dilution of wine followed by direct plumbane generation in the presence of 0.1 mol L(-1) HCl and 1% m/v K(3)[Fe(CN)(6)] with 1% m/v NaBH(4) as reducing agent. An aqueous standard calibration curve is recommended for Pb quantification in wine sample. The method provides a limit of detection and a limit of quantification of 0.3 microg L(-1) and 1 microg L(-1), respectively. The relative standard deviation varies between 2-6% (within-run) and 4-11% (between-run) at 3-30 microg L(-1) Pb levels in wine. Good agreement has been demonstrated between results obtained by CF-HGAFS and direct electrothermal atomic absorption spectrometry in analyses of red and white wines within the concentration range of 9.2-25.8 microg L(-1) Pb.Entities:
Mesh:
Substances:
Year: 2007 PMID: 17546448 DOI: 10.1007/s00216-007-1127-0
Source DB: PubMed Journal: Anal Bioanal Chem ISSN: 1618-2642 Impact factor: 4.142