Literature DB >> 17546290

Ultrasonography for measuring rectus abdominis muscles diastasis.

Denise de Almeida Mendes1, Fábio Xerfan Nahas, Daniela Francescato Veiga, Fernando Vilela Mendes, Ricardo Góes Figueiras, Heitor Carvalho Gomes, Pedro Bins Ely, Neil Ferreira Novo, Lydia Masako Ferreira.   

Abstract

PURPOSE: Preoperative imaging evaluation may be useful for determining the position of recti abdominis muscles before their correction. The purpose of this study is to evaluate the accuracy of ultrasonography to measure the width of rectus abdominis muscle diastasis.
METHODS: Rectus diastasis was measured by ultrasonography preoperatively in 20 females. Rectus diastasis was measured in seven levels along the anterior rectus sheath by ultrasound after sustained deep inspiration and after expiration. Rectus diastasis, at the same levels, was also measured after its exposition during abdominoplasty by two independent observers, using a surgical compass. These values were compared using Wilcoxon's statistical text, for non independent values.
RESULTS: There was no significant difference between the values obtained by ultrasound and those measured during surgery in the supra-umbilical levels and at the level of the umbilicus. However, below the umbilicus these values differed significantly, showing smaller values in the imaging evaluation.
CONCLUSION: Ultrasonography is an accurate method to measure rectus diastasis above the umbilicus and at the umbilical level.

Entities:  

Mesh:

Year:  2007        PMID: 17546290     DOI: 10.1590/s0102-86502007000300005

Source DB:  PubMed          Journal:  Acta Cir Bras        ISSN: 0102-8650            Impact factor:   1.388


  13 in total

1.  Totally endoscopic surgery on diastasis recti associated with midline hernias. The advantages of a minimally invasive approach. Prospective cohort study.

Authors:  Juan Bellido Luque; A Bellido Luque; J Valdivia; J M Suarez Gráu; J Gomez Menchero; J García Moreno; J Guadalajara Jurado
Journal:  Hernia       Date:  2014-08-21       Impact factor: 4.739

2.  Influence of Ultrasound Transducer Tilt in the Cranial and Caudal Directions on Measurements of Inter-Rectus Distance in Parous Women.

Authors:  Nicole F Hills; Nadia Keshwani; Linda McLean
Journal:  Physiother Can       Date:  2018       Impact factor: 1.037

Review 3.  Abdominal wall sonography: a pictorial review.

Authors:  Ferdinando Draghi; Giulio Cocco; Filippo Maria Richelmi; Cosima Schiavone
Journal:  J Ultrasound       Date:  2020-03-03

4.  Inter-Rectus Distance Measurement Using Ultrasound Imaging: Does the Rater Matter?

Authors:  Nadia Keshwani; Nicole Hills; Linda McLean
Journal:  Physiother Can       Date:  2016       Impact factor: 1.037

5.  Analysis of the abdominal musculo-aponeurotic anatomy in rectus diastasis: comparison of CT scanning and preoperative clinical assessment with direct measurement intraoperatively.

Authors:  P Emanuelsson; U Dahlstrand; U Strömsten; U Gunnarsson; K Strigård; B Stark
Journal:  Hernia       Date:  2014-02-01       Impact factor: 4.739

6.  The ultrasound diagnostic criteria for diastasis recti and its correlation with pelvic floor dysfunction in early postpartum women.

Authors:  Enze Qu; Jiawei Wu; Man Zhang; Lili Wu; Ting Zhang; Jing Xu; Xinling Zhang
Journal:  Quant Imaging Med Surg       Date:  2021-02

7.  The Digital Caliper's Interrater Reliability in Measuring the Interrecti Distance and Its Accuracy in Diagnosing the Diastasis of Rectus Abdominis Muscle in the Third Trimester of Pregnancy.

Authors:  Maíra Belo; Adriana Melo; Alexandre Delgado; Adriana Costa; Valéria Anísio; Andrea Lemos
Journal:  J Chiropr Med       Date:  2020-09-04

8.  Efficacy of deep core stability exercise program in postpartum women with diastasis recti abdominis: a randomised controlled trial.

Authors:  Ali A Thabet; Mansour A Alshehri
Journal:  J Musculoskelet Neuronal Interact       Date:  2019-03-01       Impact factor: 2.041

9.  Muscle elasticity is different in individuals with diastasis recti abdominis than healthy volunteers.

Authors:  Kai He; Xiuling Zhou; Yulan Zhu; Bo Wang; Xiaojian Fu; Qiyuan Yao; Hao Chen; Xiaohong Wang
Journal:  Insights Imaging       Date:  2021-06-29

10.  Diastasis of rectus abdominis muscles: patterns of anatomical variation as demonstrated by ultrasound.

Authors:  Antonio Corvino; Dario De Rosa; Carolina Sbordone; Antonio Nunziata; Fabio Corvino; Carlo Varelli; Orlando Catalano
Journal:  Pol J Radiol       Date:  2019-12-15
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.