Validation of rapid and simple LC-MS/MS method for determination of voriconazole in rat plasma.

B V Araujo1, D J Conrado, E C Palma, Teresa Dalla Costa.   

Abstract

A rapid, simple and sensitive LC-MS/MS analytical method was developed and validated for the determination of voriconazole (VRC) in rat plasma, using ketoconazole as internal standard (IS). Analysis was performed on a Shimadzu HPLC system using a Shimadzu C18 column and isocratic elution with acetonitrile-water-formic acid (60:40:0.05, v/v/v), at a flow of 1.0 mL/min (split ratio 1:5), and a mass spectrometer Micromass, equipped with a double quadrupole and an electrospray ionization interface, operated in a positive mode. Plasma samples were deproteinized with methanol (1:2) and 30 microL of the supernatant was injected into the system. The retention times of VRC and IS were approximately 3.3 and 2.7 min, respectively. Calibration curves in spiked plasma were linear over the concentration range of 50-2500 ng/mL with determination coefficient >0.98. The lower limit of quantification was 50 ng/mL. The accuracy of the method was within 5%. Intra- and inter-day relative standard deviations were less or equal to 12.5 and 7.7%, respectively. The applicability of the LC-MS-MS method for pharmacokinetic studies was tested using plasma samples obtained after intravenous administration of VRC to male Wistar rats. The reported method provided the necessary sensitivity, linearity, precision, accuracy, and specificity to allow the determination of VRC in pre-clinical pharmacokinetic studies.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17544609     DOI: 10.1016/j.jpba.2007.03.026

Source DB:  PubMed          Journal:  J Pharm Biomed Anal        ISSN: 0731-7085            Impact factor:   3.935


  7 in total

1.  Multiplex ultra-performance liquid chromatography-tandem mass spectrometry method for simultaneous quantification in human plasma of fluconazole, itraconazole, hydroxyitraconazole, posaconazole, voriconazole, voriconazole-N-oxide, anidulafungin, and caspofungin.

Authors:  Laurent Arthur Decosterd; Bertrand Rochat; Benoît Pesse; Thomas Mercier; Frédéric Tissot; Nicolas Widmer; Jacques Bille; Thierry Calandra; Boris Zanolari; Oscar Marchetti
Journal:  Antimicrob Agents Chemother       Date:  2010-09-20       Impact factor: 5.191

2.  Multicenter comparison of the ISO standard 20776-1 and the serial 2-fold dilution procedures to dilute hydrophilic and hydrophobic antifungal agents for susceptibility testing.

Authors:  Alicia Gomez-Lopez; Maiken Cavling Arendrup; Cornelia Lass-Floerl; Juan-Luis Rodriguez-Tudela; Manuel Cuenca-Estrella
Journal:  J Clin Microbiol       Date:  2010-03-10       Impact factor: 5.948

3.  Influence of Experimental Cryptococcal Meningitis in Wistar Rats on Voriconazole Brain Penetration Assessed by Microdialysis.

Authors:  Izabel Almeida Alves; Keli Jaqueline Staudt; Carolina de Miranda Silva; Graziela de Araujo Lock; Teresa Dalla Costa; Bibiana Verlindo de Araujo
Journal:  Antimicrob Agents Chemother       Date:  2017-06-27       Impact factor: 5.191

4.  Pilot investigation on long-term subcutaneous microdialysis: proof of principle in humans.

Authors:  Franziska Simmel; Claudia Kirbs; Zeynep Erdogan; Edith Lackner; Markus Zeitlinger; Charlotte Kloft
Journal:  AAPS J       Date:  2012-10-13       Impact factor: 4.009

Review 5.  Therapeutic drug monitoring (TDM) of antifungal agents: guidelines from the British Society for Medical Mycology.

Authors:  H Ruth Ashbee; Rosemary A Barnes; Elizabeth M Johnson; Malcolm D Richardson; Rebecca Gorton; William W Hope
Journal:  J Antimicrob Chemother       Date:  2013-12-29       Impact factor: 5.790

Review 6.  Assessment of greenness for the determination of voriconazole in reported analytical methods.

Authors:  Hemanth Kumar Chanduluru; Abimanyu Sugumaran
Journal:  RSC Adv       Date:  2022-02-28       Impact factor: 3.361

7.  Performance evaluation of enzyme immunoassay for voriconazole therapeutic drug monitoring with automated clinical chemistry analyzers.

Authors:  Yongbum Jeon; Minje Han; Eun Young Han; Kyunghoon Lee; Junghan Song; Sang Hoon Song
Journal:  Pract Lab Med       Date:  2017-05-13
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.