Abdominal aortic and left common iliac aneurysms in a 79-year-old man who had undergone Miles' operation for rectal carcinoma were treated with endovascular repair of an abdominal aortic aneurysm (EVAR), taking into consideration the age, surgical history, and wishes of the patient and his family. The Matsui-Kitamura stent-graft (MK-SG) was designed based on preoperative angiographic mapping. At EVAR, the right leg of the MK-SG was caught at the aortic bifurcation because of unexpected contraction of the MK-SG. To resolve the problem, the body of the MK-SG was dilated with a balloon, slightly lifted while being gradually shortened, and eventually successfully connected to the leg of the MK-SG. Made of nitinol mesh, the MK-SG is stable and flexible enough to make it one of the best stent-grafts for EVAR. A serious drawback, however, is the high contraction rate of the MK-SG itself. It is difficult to estimate the appropriate length of the stent-graft owing to unpredictable contraction. It is important to understand its characteristics and to carefully design and acquire sufficient skills in manipulating MK-SG.

Entities:  

Mesh:

Year:  2007        PMID: 17541517     DOI: 10.1007/s11604-006-0099-x

Source DB:  PubMed          Journal:  Radiat Med        ISSN: 0288-2043


  8 in total

1.  Endoleak after endovascular repair of abdominal aortic aneurysm.

Authors:  T A Chuter; R M Faruqi; R Sawhney; L M Reilly; R B Kerlan; C J Canto; G C Lukaszewicz; J M Laberge; M W Wilson; R L Gordon; S D Wall; J Rapp; L M Messina
Journal:  J Vasc Surg       Date:  2001-07       Impact factor: 4.268

2.  Distal embolus protection with an intra-aortic filter during stent-graft repair of a severely atherosclerotic thoracic aortic aneurysm.

Authors:  Junichiro Sanada; Osamu Matsui; Hiroshi Ohtake; Keiichi Kimura; Miho Kusanagi; Noboru Terayama
Journal:  J Endovasc Ther       Date:  2005-12       Impact factor: 3.487

3.  Endovascular stent-grafting for infected iliac artery pseudoaneurysms.

Authors:  Junichiro Sanada; Osamu Matsui; Fumitaka Arakawa; Mari Tawara; Tamao Endo; Hiroshi Ito; Satoshi Ushijima; Masamitsu Endo; Masahiro Ikeda; Katsuyuki Miyazu
Journal:  Cardiovasc Intervent Radiol       Date:  2005 Jan-Feb       Impact factor: 2.740

4.  Endoluminal stent-grafts for infrarenal abdominal aortic aneurysms.

Authors:  U Blum; G Voshage; J Lammer; F Beyersdorf; D Töllner; G Kretschmer; G Spillner; P Polterauer; G Nagel; T Hölzenbein
Journal:  N Engl J Med       Date:  1997-01-02       Impact factor: 91.245

5.  Incidence and risk factors of late rupture, conversion, and death after endovascular repair of infrarenal aortic aneurysms: the EUROSTAR experience. European Collaborators on Stent/graft techniques for aortic aneurysm repair.

Authors:  P L Harris; S R Vallabhaneni; P Desgranges; J P Becquemin; C van Marrewijk; R J Laheij
Journal:  J Vasc Surg       Date:  2000-10       Impact factor: 4.268

6.  Mediastinal bronchial artery aneurysm treated with a stent-graft.

Authors:  Fuminori Kasashima; Masamitsu Endo; Ikuko Kosugi; Yasushi Matsumoto; Yoshinobu Abe; Hisao Sasaki; Junichiro Sanada; Osamu Matsui
Journal:  J Endovasc Ther       Date:  2003-04       Impact factor: 3.487

7.  Clinical application of a curved nitinol stent-graft for thoracic aortic aneurysms.

Authors:  Junichiro Sanada; Osamu Matsui; Noboru Terayama; Satoshi Kobayashi; Tetsuya Minami; Masahiro Kurozumi; Hiroshi Ohtake; Hiroshi Urayama; Masamitsu Endo
Journal:  J Endovasc Ther       Date:  2003-02       Impact factor: 3.487

8.  Transfemoral intraluminal graft implantation for abdominal aortic aneurysms.

Authors:  J C Parodi; J C Palmaz; H D Barone
Journal:  Ann Vasc Surg       Date:  1991-11       Impact factor: 1.466

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.