Literature DB >> 17540741

Isolated acetabular liner exchange compared with complete acetabular component revision in revision of primary uncemented acetabular components: a study of 1649 revisions from the Norwegian Arthroplasty Register.

S A Lie1, G Hallan, O Furnes, L I Havelin, L B Engesaeter.   

Abstract

We analysed the results of different strategies in the revision of primary uncemented acetabular components reported to the Norwegian Arthroplasty Register. The aim was to compare the risk of further acetabular revision after isolated liner exchange and complete component revision. The results of exchanging well-fixed components were also compared with those of exchanging loose acetabular components. The period studied was between September 1987 and April 2005. The following groups were compared: group 1, exchange of liner only in 318 hips; group 2, exchange of well-fixed components in 398; and group 3, exchange of loose components in 933. We found that the risk of a further cup revision was lower after revision of well-fixed components (relative risk from a Cox model (RR) = 0.56, 95% confidence interval 0.37% to 0.87%) and loose components (RR = 0.56, 95% confidence interval 0.39% to 0.80%), compared with exchange of the liner in isolation. The most frequent reason for a further acetabular revision was dislocation, accounting for 61 (28%) of the re-revisions. Other reasons for further revision included pain in 27 (12%), loosening in 24 (11%) and infection in 20 (9%). Re-revisions because of pain were less frequent when complete component (fixed or loose) revision was undertaken compared with isolated exchange of the liner (RR = 0.20 (95% confidence interval 0.06% to 0.65%) and RR = 0.10 (95% confidence interval 0.03% to 0.30%), respectively). The risk of further acetabular revision for infection, however, did not differ between the groups. In this study, exchange of the liner only had a higher risk of further cup revision than revision of the complete acetabular component. Our results suggest that the threshold for revising well-fixed components in the case of liner wear and osteolysis should be lowered.

Entities:  

Mesh:

Year:  2007        PMID: 17540741     DOI: 10.1302/0301-620X.89B5.18623

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  7 in total

1.  Method of fixation does not influence the overall risk of rerevision in first-time cup revisions.

Authors:  Maziar Mohaddes; Göran Garellick; Johan Kärrholm
Journal:  Clin Orthop Relat Res       Date:  2013-12       Impact factor: 4.176

2.  Uncemented and cemented primary total hip arthroplasty in the Swedish Hip Arthroplasty Register.

Authors:  Nils P Hailer; Göran Garellick; Johan Kärrholm
Journal:  Acta Orthop       Date:  2010-02       Impact factor: 3.717

3.  Isolated polyethylene exchange versus acetabular revision for polyethylene wear.

Authors:  Camilo Restrepo; Elie Ghanem; Carrie Houssock; Mathew Austin; Javad Parvizi; William J Hozack
Journal:  Clin Orthop Relat Res       Date:  2008-10-10       Impact factor: 4.176

4.  Prosthesis infections after orthopedic joint replacement: the possible role of bacterial biofilms.

Authors:  Zhijun Song; Lotte Borgwardt; Niels Høiby; Hong Wu; Torben Sandberg Sørensen; Arne Borgwardt
Journal:  Orthop Rev (Pavia)       Date:  2013-06-14

5.  Isolated Acetabular Liner Exchange for Polyethylene Wear and Osteolysis with Well-Fixed Metal Shell.

Authors:  Kyung Wook Kim; Jeong Joon Yoo; Min Nyun Kim; Hee Joong Kim
Journal:  Clin Orthop Surg       Date:  2019-08-12

6.  To cement or not to cement acetabular cups in total hip arthroplasty: a systematic review and re-evaluation.

Authors:  Frank Van Praet; Michiel Mulier
Journal:  SICOT J       Date:  2019-10-01

7.  High risk of hip dislocation following polyethylene liner exchange in total hip arthroplasty-is cup revision necessary?

Authors:  D Dammerer; F Schneider; T Renkawitz; D Putzer; M Bogensperger; R Biedermann
Journal:  Arch Orthop Trauma Surg       Date:  2020-09-19       Impact factor: 3.067

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.