Literature DB >> 17540393

Comparative study of an estradiol enzyme-linked immunosorbent assay kit, liquid chromatography-tandem mass spectrometry, and ultra performance liquid chromatography-quadrupole time of flight mass spectrometry for part-per-trillion analysis of estrogens in water samples.

Marinella Farré1, Marina Kuster, Rikke Brix, Fernando Rubio, María-J López de Alda, Damià Barceló.   

Abstract

Estrogens have been often identified as the major contributors to the endocrine-disrupting activity observed in environmental waters. However, their analysis in these, sometimes very complex, matrices is still challenging due to the very low detection limits and the selectivity required for their reliable determination at the very low concentrations at which they are physiologically active. In this work, a polyclonal enzyme-linked immunosorbent assay (ELISA) kit for 17-beta-estradiol analysis, high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) based on triple-quadrupole analyzer (QqQ), and a newly developed method based on ultra performance liquid chromatography-quadrupole time of flight mass spectrometry (UPLC-Q-TOF-MS) have been evaluated in terms of performance for the rapid screening, quantitative analysis, and unequivocal identification of some selected, environmentally relevant estrogens in different water matrices, including urban wastewater, river water, and ground water, after solid phase extraction. Compounds quantified and/or identified included the estrogens 17-beta-estradiol, estrone, 17-alpha-ethynyl estradiol and estriol, and the isoflavones daidzein, genistein, and biochanin A. Except for a moderate overestimation using the ELISA kit, especially in the analysis of complex wastewater samples, results obtained by all the investigated techniques were in very good, general agreement. The instrumental sensitivity achieved increased in the order: UPLC-Q-TOF-MS < polyclonal ELISA kit < HPLC-MS/MS (QqQ). Direct analysis of water samples by using the ELISA kit permitted to reach a limit of detection of 2.5 ng L(-1). However, using an appropriated sample pretreatment method detection limits at nanogram to picogram per liter levels can be obtained with all techniques and the risk for matrix effects is minimized. In terms of selectivity, both HPLC-MS/MS (QqQ) and UPLC-Q-TOF-MS show outstanding performance, but the latter allows, in addition, shorter analysis times (16 min vs. 45 min) and the identification of non-target, unknown compounds. The identification of unknown compounds is based on the accurate mass measurements for the precursor and product ions, that permit the elemental compositions calculation and the chemical structures to be identified searching against different databases.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17540393     DOI: 10.1016/j.chroma.2007.05.032

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  6 in total

1.  Rapid measurement of estrogens and their metabolites in human serum by liquid chromatography-tandem mass spectrometry without derivatization.

Authors:  Tiedong Guo; Jianghong Gu; Offie P Soldin; Ravinder J Singh; Steven J Soldin
Journal:  Clin Biochem       Date:  2008-03-07       Impact factor: 3.281

Review 2.  Procedures of determining organic trace compounds in municipal sewage sludge-a review.

Authors:  Petra C Lindholm-Lehto; Heidi S J Ahkola; Juha S Knuutinen
Journal:  Environ Sci Pollut Res Int       Date:  2016-12-13       Impact factor: 4.223

3.  Impact of immobilization technology in industrial and pharmaceutical applications.

Authors:  Mohamed E Hassan; Qingyu Yang; Zhigang Xiao; Lu Liu; Na Wang; Xiaotong Cui; Liu Yang
Journal:  3 Biotech       Date:  2019-11-08       Impact factor: 2.406

4.  A Simple Method for Automated Solid Phase Extraction of Water Samples for Immunological Analysis of Small Pollutants.

Authors:  Sarah Heub; Noe Tscharner; Florian Kehl; Petra S Dittrich; Stéphane Follonier; Laurent Barbe
Journal:  J Vis Exp       Date:  2016-01-01       Impact factor: 1.355

5.  17β-Estradiol influent and effluent concentrations in wastewater: demographic influences and the risk to environmental health.

Authors:  K T Heffron; K F Gaines; J M Novak; T Canam; D A Collard
Journal:  Environ Monit Assess       Date:  2016-04-13       Impact factor: 2.513

6.  Biomimetic receptors for bioanalyte detection by quartz crystal microbalances - from molecules to cells.

Authors:  Usman Latif; Jianjin Qian; Serpil Can; Franz L Dickert
Journal:  Sensors (Basel)       Date:  2014-12-05       Impact factor: 3.576

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.