Anterior or posterior obliquity of the lag screw in the lateral view--does it affect the sliding characteristics on unstable trochanteric fractures?

Si Young Park1, Jin Park, Dong Joo Rhee, Han Kook Yoon, Kyu Hyun Yang.   

Abstract

We investigated the sliding pattern characteristics of proximal fragment in 16 proximal femur models of 31-A2.1 type trochanteric fractures fixed with dynamic hip screw system under load. In eight models, the lag screw was inserted with an anterior-to-posterior vector within the neck and the head of femur (group 1). The other eight had a posterior-to-anterior vector (group 2). A force of 500 N (30 cycles) was applied to the fracture fragment-plate complex using the Instron 6022. No significant difference was noted in the sliding distance between the two groups (p=0.17). However, the mean angle of rotation of the proximal fragment was twice as great in group 1 (16+/-3.7 degrees ) than that in group 2 (8.1+/-1.5 degrees ) (p<0.001). In group 1, early eccentric contact in the anterior aspect of the intertrochanteric area caused internal rotation of the proximal fragment. Breakage of the anterior cortex of the lateral wall was noted in five out of the eight cases in group 1 and no case in group 2 (p=0.026). Fracture of the anterior cortices significantly threatened the integrity of the lateral wall in group 1.

Entities:  

Mesh:

Year:  2007        PMID: 17540377     DOI: 10.1016/j.injury.2007.03.010

Source DB:  PubMed          Journal:  Injury        ISSN: 0020-1383            Impact factor:   2.586


  3 in total

1.  Which AO/OTA 31-A2 pertrochanteric fractures can be treated with a dynamic hip screw without developing a lateral wall fracture? A CT-based study.

Authors:  Gaurav Sharma; Ravijot Singh; Kiran Kumar Gn; Vaibhav Jain; Ankit Gupta; Shivanand Gamanagatti; Kamran Farooque; Vijay Sharma
Journal:  Int Orthop       Date:  2015-07-04       Impact factor: 3.075

2.  A biomechanical study comparing helical blade with screw design for sliding hip fixations of unstable intertrochanteric fractures.

Authors:  Qiang Luo; Grace Yuen; Tak-Wing Lau; Kelvin Yeung; Frankie Leung
Journal:  ScientificWorldJournal       Date:  2013-02-20

3.  Accurate and Easy Measurement of Sliding Distance of Intramedullary Nail in Trochanteric Fracture.

Authors:  Nobuaki Chinzei; Takafumi Hiranaka; Takahiro Niikura; Takaaki Fujishiro; Shinya Hayashi; Noriyuki Kanzaki; Shingo Hashimoto; Yoshitada Sakai; Ryosuke Kuroda; Masahiro Kurosaka
Journal:  Clin Orthop Surg       Date:  2015-05-18
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.