Ultrasound focal lesion detectability phantoms.

E L Madsen1, J A Zagzebski, M C Macdonald, G R Frank.   

Abstract

Two phantoms for assessing the performance of ultrasound scanners regarding detectability of small focal lesions are described. The spherical simulated lesions in the phantoms have diameters of 2.4, 3.0, and 4.0 mm and backscatter coefficients which are 16, 9, and 6 dB below that of the surrounding tissue-mimicking material, the latter simulating normal tissue such as liver. Random positioning and relatively large numbers of lesions deal with the statistical problem related to mistaking a normal textural fluctuation, characteristic of ultrasound images of parenchymal tissue, to be a small lesion. All lesions have ultrasonic properties that are the same as those of the surrounding material except for the backscatter coefficient; therefore, artifacts resulting from attenuation, reverberation, and/or refraction are absent, and detectability of deeper lesions is not influenced by the presence of more proximal ones. A method is outlined for using the phantoms to determine bounding proximal and distal depths of resolution, or detectability, of focal lesions of a given object contrast and size. Tests for observer dependence involving five subjects resulted in standard deviations in the distal and proximal depths of less than 0.5 cm. A repeat of the observer dependence tests 18 months later showed little change in the results. In addition, results obtained by two experienced observers are also given for a variety of specific scanners, scanning heads, and scanning parameters.

Entities:  

Mesh:

Year:  1991        PMID: 1753901     DOI: 10.1118/1.596589

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  4 in total

1.  Development of a catheter for combined intravascular ultrasound and photoacoustic imaging.

Authors:  Andrei B Karpiouk; Bo Wang; Stanislav Y Emelianov
Journal:  Rev Sci Instrum       Date:  2010-01       Impact factor: 1.523

2.  Development and characterization of a tissue mimicking psyllium husk gelatin phantom for ultrasound and magnetic resonance imaging.

Authors:  Lorne W Hofstetter; Lewis Fausett; Alexander Mueller; Henrik Odéen; Allison Payne; Douglas A Christensen; Dennis L Parker
Journal:  Int J Hyperthermia       Date:  2020       Impact factor: 3.914

3.  Acoustic Properties of Breast Fat.

Authors:  Haidy Gerges Nasief; Ivan M Rosado-Mendez; James A Zagzebski; Timothy J Hall
Journal:  J Ultrasound Med       Date:  2015-10-07       Impact factor: 2.153

4.  Comparison of the low-contrast detectability of two ultrasound systems using a grayscale phantom.

Authors:  Robert Lorentsson; Nasser Hosseini; Jan-Olof Johansson; Wiebke Rosenberg; Benny Stenborg; Lars Gunnar Månsson; Magnus Båth
Journal:  J Appl Clin Med Phys       Date:  2016-11-08       Impact factor: 2.102

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.