Image-free cup navigation inaccuracy: a two-study approach.

Sorin Blendea1, Jocelyne Troccaz, Jean-Noel Ravey, Philippe Merloz.   

Abstract

The present study tested the accuracy of an image-free navigation system used for total hip arthroplasty (THA). Two parallel, prospective studies were performed: one on real patients and the other on pelvic phantoms. We used a comparison between the intra-operative cup orientation, as displayed by the navigation system, and the post-operative cup position, as measured on CT data. The mean intrinsic overall error (+/- standard deviation) found in the phantom study was 2.6 +/- 1.1 degrees (range: 1.5-4.4 degrees ) for cup abduction, and 0.9 +/- 0.7 degrees (range: 0-2.5 degrees ) for cup anteversion. The system was less accurate in the clinical operative setting. The evaluation model was able to identify, and more importantly quantify, the clinically induced error. Ameliorating this would improve the clinical accuracy of the system.

Entities:  

Mesh:

Year:  2007        PMID: 17538790     DOI: 10.3109/10929080701374265

Source DB:  PubMed          Journal:  Comput Aided Surg        ISSN: 1092-9088


  5 in total

1.  Measuring acetabular component version after THA: CT or plain radiograph?

Authors:  Benjamin McArthur; Michael Cross; Christina Geatrakas; David Mayman; Bernard Ghelman
Journal:  Clin Orthop Relat Res       Date:  2012-03-01       Impact factor: 4.176

2.  Intra- and intersurgeon variability in image-free navigation system for THA.

Authors:  Hirotsugu Ohashi; Masanori Matsuura; Yusaku Okamoto; Yoshiaki Okajima
Journal:  Clin Orthop Relat Res       Date:  2009-04-21       Impact factor: 4.176

3.  Accuracy of acetabular cup positioning using imageless navigation.

Authors:  Erik Hohmann; Adam Bryant; Kevin Tetsworth
Journal:  J Orthop Surg Res       Date:  2011-08-10       Impact factor: 2.359

4.  Comparison of Cup Setting Angle Accuracy between Computed Tomography-Based and Computed Tomography-Free Navigation in the Same Patients with Crowe's Classification I or II Hip Dysplasia.

Authors:  Nobuhiro Kaku; Hiroaki Tagomori; Hiroshi Tsumura
Journal:  Clin Orthop Surg       Date:  2021-04-12

5.  Accuracy of cup placement in total hip arthroplasty by means of a mechanical positioning device: a comprehensive cadaveric 3d analysis of 16 specimens.

Authors:  Arthur J Kievit; Johannes G G Dobbe; Wouter H Mallee; Leendert Blankevoort; Geert J Streekstra; Matthias U Schafroth
Journal:  Hip Int       Date:  2019-09-11       Impact factor: 2.135