Literature DB >> 17538134

Fate of migrated esophageal and gastroduodenal stents: experience in 70 patients.

Heung-Kyu Ko1, Ho-Young Song, Ji Hoon Shin, Gin Hyug Lee, Hwoong-Yong Jung, Seung-Il Park.   

Abstract

PURPOSE: To investigate the frequency of esophageal and gastroduodenal stent migration and the fate of such stents.
MATERIALS AND METHODS: The authors studied five types of covered metal stents. Type A stents were nonretrievable polyurethane-covered stents with shouldered ends (n = 169), type B stents were retrievable polyurethane-covered stents with shouldered ends (n = 62), type C stents were retrievable polyurethane-covered stents with flared ends (n = 72), type D stents were retrievable polytetrafluoroethylene-covered stents with shouldered ends (n = 369), and type E stents were separated stents (n = 216). Types A-D stents were esophageal stents, and the type E stent was a gastroduodenal stent. Stents were placed in 888 patients with either benign (n = 43) or malignant (n = 845) causes of stricture. The rate of stent migration was analyzed relative to completeness of migration, the cause of obstruction, stent type, and stent placement location. The fate of migrated stents and the treatment of patients were evaluated.
RESULTS: Stent migration occurred in 70 of the 888 patients (7.9%). Migration occurred in 11 of the 43 patients (25%) with benign cause of strictures and 591 of the 845 patients (7.0%) with malignant cause. The migration rates for types A, B, C, D, and E stents were 10%, 4.8%, 24%, 7.3% and 2.8%, respectively. Of the 70 migrated stents, 45 had complete migration and 25 had partial migration. The anastomotic sites were the areas most commonly associated with migration (16%), but this was not statistically significant. Forty of the 70 migrated stents were removed with retrieval devices under fluoroscopic guidance because they were not passed with stool and possibility of complications related to migrated stents. The remaining 30 stents exited via the rectum (n = 15), remained in the body without complications (n = 12), or were surgically removed because they caused complicated intestinal obstructions (n = 3).
CONCLUSION: The overall migration rate for esophageal and gastroduodenal stents was 7.9%. Most migrated stents were removed nonsurgically, exited the body spontaneously, or remained in the body in an uncomplicated state. Surgical stent removal was necessary in three patients (4.3%) due to complicated intestinal obstructions.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17538134     DOI: 10.1016/j.jvir.2007.02.030

Source DB:  PubMed          Journal:  J Vasc Interv Radiol        ISSN: 1051-0443            Impact factor:   3.464


  10 in total

1.  Long-term outcome after endoscopic stent therapy for complications after bariatric surgery.

Authors:  Atif Iqbal; Brent Miedema; Archana Ramaswamy; Nicole Fearing; Roger de la Torre; Youngju Pak; Caleb Stephen; Klaus Thaler
Journal:  Surg Endosc       Date:  2010-07-13       Impact factor: 4.584

2.  Endoscopic suture fixation of self-expanding metallic stents with and without submucosal injection.

Authors:  Victor T Wilcox; Albert Y Huang; Nabil Tariq; Brian J Dunkin
Journal:  Surg Endosc       Date:  2014-08-27       Impact factor: 4.584

3.  How to design the optimal self-expandable oesophageal metallic stents: 22 years of experience in 645 patients with malignant strictures.

Authors:  Han Kyu Na; Ho-Young Song; Jin Hyoung Kim; Jung-Hoon Park; Min Kyoung Kang; Jongjin Lee; Se Jin Oh
Journal:  Eur Radiol       Date:  2012-09-27       Impact factor: 5.315

4.  Esophageal stent migration can lead to intestinal obstruction.

Authors:  Oguzhan Karatepe; Ersin Acet; Merih Altiok; Muharrem Battal; Gokhan Adas; Servet Karahan
Journal:  N Am J Med Sci       Date:  2009-07

5.  Efficacy of Retrievable Metallic Stent with Fixation String for Benign Stricture after Upper Gastrointestinal Surgery.

Authors:  Jeong-Eun Kim; Hyo-Cheol Kim; Myungsu Lee; Saebeom Hur; Minuk Kim; Sang Hwan Lee; Soo Buem Cho; Chan Sun Kim; Joon Koo Han
Journal:  Korean J Radiol       Date:  2016-10-31       Impact factor: 3.500

6.  Fully-covered metal stents with endoscopic suturing vs. partially-covered metal stents for benign upper gastrointestinal diseases: a comparative study.

Authors:  Saowanee Ngamruengphong; Reem Sharaiha; Amrita Sethi; Ali Siddiqui; Christopher J DiMaio; Susana Gonzalez; Jason Rogart; Sophia Jagroop; Jessica Widmer; Jennifer Im; Raza Abbas Hasan; Sobia Laique; Tamas Gonda; John Poneros; Amit Desai; Katherine Wong; Vipin Villgran; Olaya Brewer Gutierrez; Majidah Bukhari; Yen-I Chen; Ruben Hernaez; Yuri Hanada; Omid Sanaei; Amol Agarwal; Anthony N Kalloo; Vivek Kumbhari; Vikesh Singh; Mouen A Khashab
Journal:  Endosc Int Open       Date:  2018-02-02

7.  Migrated esophageal stent posing a challenge for ventilation.

Authors:  Nita D'souza; Sachin Arbhi; Amit Dikshit; Murarji Ghadge; Smriti Jha
Journal:  Saudi J Anaesth       Date:  2017 Apr-Jun

8.  Efficacy of Gastric Balloon Dilatation and/or Retrievable Stent Insertion for Pyloric Spasms after Pylorus-Preserving Gastrectomy: Retrospective Analysis.

Authors:  Jae Seok Bae; Se Hyung Kim; Cheong-Il Shin; Ijin Joo; Jeong Hee Yoon; Hyuk-Joon Lee; Han-Kwang Yang; Jee Hyun Baek; Tae Han Kim; Joon Koo Han; Byung Ihn Choi
Journal:  PLoS One       Date:  2015-12-10       Impact factor: 3.240

9.  Oesophageal stent migration following Billroth I gastrectomy: an unusual cause of small bowel obstruction.

Authors:  Morgan Quinn; David Luke
Journal:  J Surg Case Rep       Date:  2013-02-18

Review 10.  Endoscopic management of gastrointestinal leaks and fistulae: What option do we have?

Authors:  Fabrizio Cereatti; Roberto Grassia; Andrea Drago; Clara Benedetta Conti; Gianfranco Donatelli
Journal:  World J Gastroenterol       Date:  2020-08-07       Impact factor: 5.742

  10 in total